AXIS Q1604-E Network Camera
Technical Specifications
Note
The I/O connector is connected to the housing (fan/heater) on delivery. In the case of a fan or heater error, an input signal will be triggered in the camera. Set up an action rule in the camera to configure which action the signal shall trigger. For information about events and action rules, see Events, on page 37.
Function | Pin | Notes | Specifications | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0 V DC | 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 V DC | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DC output | 2 | Can be used to power auxiliary equipment. | 3.3 V DC | |||||||||||||||||
|
| Note: This pin can only be used as power out. | Max load = 50 mA | |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Digital Input | 3 | Connect to pin 1 to activate, or leave floating (unconnected) | 0 to max 40 V DC | |||||||||||||||||
|
| to deactivate |
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Digital Output | 4 | Connected to pin 1 when activated, floating (unconnected) | 0 to max 40 V DC, open drain, | |||||||||||||||||
|
| when deactivated. If used with an inductive load, e.g. a relay, | 100 mA | |||||||||||||||||
|
| a diode must be connected in parallel with the load, for |
|
| ||||||||||||||||
|
| protection against voltage transients. |
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Power Connector
DC power input | |
Use a Safety Extra Low Voltage (SELV) |
|
compliant limited power source (LPS) |
|
with either a rated output power |
|
limited to ≤100 W or a rated output |
|
current limited to ≤5 A. |
|
63