Page 16

AXIS 215 PTZ Installation Guide

Connection diagram

AXIS 215 PTZ

12V

max. 100mA

1o

e.g. pushbutton

2o

z

3 o

4

o

LED indicators

LED

Color

Indication

 

 

 

Network

Green

Steady for connection to a 100 Mbit/s network. Flashes for network activity.

 

 

 

 

Amber

Steady for connection to 10 Mbit/s network. Flashes for network activity.

 

 

 

 

Unlit

No network connection.

 

 

 

Status

Green

Steady green for normal operation.

 

 

 

 

Amber

Steady during startup, during reset to factory default or when restoring settings.

 

 

 

 

Red

Slow flash for failed upgrade.

 

 

 

Power

Green

Normal operation.

 

 

 

 

Amber

Flashes green/amber during firmware upgrade.

 

 

 

Resetting to the Factory Default Settings

This will reset all parameters, including the IP address, to the factory default settings:

1.Disconnect power from the camera.

2.Press and hold the Control button and reconnect power.

3.Keep the Control button pressed until the Status indicator displays amber (this may take up to 15 seconds), then release the button.

4.When the Status indicator displays green (which can take up to 1 minute) the process is complete and the camera has been reset.

5.Re-assign the IP address, using one of the methods described in this document.

It is also possible to reset parameters to the original factory default settings via the web interface. For more information, please see the online help or the user’s manual.