AXIS M1034-W Network Camera
System Options
Advanced

Scripting

Scripting allows experienced users to customize and use their own scripts.

NOTICE

Improper use may cause unexpected behavior and loss of contact with the Axis product.
Axis strongly recommends that you do not use this function unless you understand the consequences. Axis Support does not provide
assistance for problems with customized scripts.
To open the Script Editor, go to System Options > Advanced > Scripting. It is recommended to create a backup le before
customizing the scripts. If a script causes problems, reset the product to its factory default settings, see

page 51

.
For more information, see www.axis.com/developer

File Upload

Files, for example web pages and images, can be uploaded to the Axis product and used as custom settings. To upload a le, go
to System Options > Advanced > File Upload.
Uploaded les are accessed through http://<ip address>/local/<user>/<file name> where<user> is the
selected user group (viewer, operator or administrator) for the uploaded le.

Plain Cong

Plain Cong is for advanced users with experience of Axis product conguration. Most parameters can be set and modied from this
page. Help is available from the standard help pages.
To open Plain Cong, go to System Options > Advanced > Plain Cong.
Reset to Factory Default Settings
This will reset all parameters, including the IP address, to the factory default settings:
1. Disconnect power from the product.
2. Press and hold the Control button and reconnect power (see

Hardware Overview, on page 6

).
3. Keep the Control button pressed for about 15 seconds until the Status indicator ashes amber.
4. Release the Control button. The process is complete after about 1 minute (when the Status indicator turns green). The
product has been reset to the factory default settings. The default IP address is 192.168.0.90
5. Re-assign the IP address.
It is also possible to reset parameters to factory default via the web interface. Go to Setup > System Options > Maintenance.
51