AXIS P3367–VE Fixed Dome Network Camera
Hardw are overv iew
Digital Input 3Connect to GND to activate, or leave floating (unconnected)
to deactivate.
0to+40VDC
Digital Output 4Internal connection to ground when activated, floating
(unconnected) when deactivated. If used with an external
relay, a diode must be connected in parallel with the load, for
protection against voltage transients.
Max load =100 mA
Max voltage = +40 V DC
LED indicators
LED Color Indication
Green Steady for connection to a 100 MBit/s network. Flashes for network activity.
Amber Steady for connection to a 10 MBit/s network. Flashes for network activity.
Network
Unlit No network connection.
Green Steady green for normal operation.
Amber Steady during startup and when restoring settings.
Status
Red Slow flash for failed upgrade.
Green Normal operation.
Power
Amber Flashes green/amber during firmware upgrade.
Note
• The Status LED can be configured to be unlit during normal operation, or to flash only when the product is accessed. To
configure, go to Setup > System Options > Ports & Devices > LED. See the online help for more information.
• The Status LED can be configured to flash while an event is active.
• The Status LED can be configured to flash for identifying the unit. This can be done under Setup >System Options>
Maintenance.
6