RS-232 Mode

To configure the port for RS-232 mode, 5 jumpers must be set/checked. The following settings will configure the port as RS- 232:

1.Set four jumpers of JP2 (A-D) to the "232" (left) position.

2.Set JP1 to the "RTS(232)" (right) position.

The remaining jumpers, JP4, are unused in the RS-232 mode and may be in either position. Figure 2 shows the jumper configuration to set the port for RS-232 mode with *1 clock enabled.

 

JP2

422/ 485

 

JP1

A 232

 

 

CONTROL

B 232

 

 

422/ 485

SD

 

 

RTS(232)

C232

 

 

422/ 485

 

 

 

 

 

 

 

 

 

 

D232

 

 

422/ 485

 

 

 

 

 

MODES

 

 

TX 422

485

 

JP3

RX 422

485 JP4

 

I N

OUT

*4

*1

TERMI NATI ON

 

CLOCK

Figure 2. RS-232 Mode Jumper Settings

RS-232 Pinouts

The DB-25 male connector on the 3PCIOSD1x cards is configured as standard DTE RS-232 serial port. Table 1 lists pin numbers and descriptors.

 

Name

Description

Direction

 

DB25M Pin

 

 

Shield

Shield

------

 

1

 

 

TD

Transmit Data

Output

 

2

 

 

RD

Receive Data

Input

 

3

 

 

RTS

Request to Send

Output

 

4

 

 

CTS

Clear to Send

Input

 

5

 

 

DSR

Data Set Ready

Input

 

6

 

 

GND

Signal Ground

------

 

7

 

 

DCD

Data Carrier Detect

Input

 

8

 

 

DTR

Data Terminal Ready

Output

 

20

 

 

 

Table 1: RS-232 Pinouts

 

 

 

 

 

 

 

 

 

 

Documentation Number 3PCIOSD1x-3903m Manual

Chapter 2

7

RS-422 Mode

To configure the port for RS-422 mode, 7 jumpers must be set/checked. The following settings configure the port as RS-422:

1.Set the four jumpers of JP2 (A-D) to the "422/485" (right) position.

2.Set the top jumper "TX" of JP4 to the “422” (left) position.

3.Set the second jumper "RX" of JP4 to the “422” (left) position.

4.The JP1 Control (SD/RTS) jumper is unused in the RS-422 mode and may be in either position.

5.The bottom jumper "Termination" of JP4 switches the 120Ω receiver termination resistor IN or OUT. Typically this resistor is not used. In some cases using high baud rates and very long cables, termination is needed. See B&B’s free RS-422/485 Application Note, Termination section, page 16, for more information (available on our websites). Figure 3 shows the jumper configuration to set the port for RS-422 mode with *1 clock enabled.

 

JP2

422/ 485

 

JP1

A 232

 

 

CONTROL

B 232

 

 

422/ 485

SD

 

RTS(232)

C232

 

 

422/ 485

 

 

 

 

 

 

 

 

D232

 

 

422/ 485

 

 

 

 

MODES

 

 

TX 422

485

 

JP3

RX 422

485 JP4

 

I N

OUT

*4

*1

TERMI NATI ON

 

CLOCK

Figure 3. RS-422 Mode Jumper Settings

8

Chapter 2

Documentation Number 3PCIOSD1x-3903m Manual

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Mfg Co – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

B&B Electronics Ltd – Westlink Comm. Pk. – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

Page 6
Image 6
B&B Electronics 3PCIOSD1x-3903m manual RS-232 Mode, RS-422 Mode, Name Description Direction DB25M Pin