B&K 1794 instruction manual No DPM Indication

Models: 1794

1 42
Download 42 pages 18.04 Kb
Page 22
Image 22

( D ) NO DPM INDICATION.

NO DPM INDICATION

Is Display Completely Blank ?

N

Does Display shows only dot Indication ?

Y

Is Continuity between IC7905 &

DPM's OK ?

Y

Is Continuity between ANGD & DPM's OK ?

Y

Is DPM IC OK ?

N

Replace It.

Y

Is Continuity between

 

IC7805 & DPM OK ?

 

N

 

Ensure proper Continuity.

N

Ensure proper Continuity.

N

Ensure proper Continuity.

 

1.If there is no Indication at all ensure that there is proper Continuity between +5V Wire of DPM's and IC7805. It might be possible that +5V Wire Crimping might be loose or IC7805 might be Damaged.

2.It DPM shows only a Dot Indication. Check whether -5V from IC 7905 is reaching DPM's. It might be possible that -5V Wire Crimping might be loose or IC 7905 might be Damaged.

3.If DPM shows Dot Indication, check whether AGND ( Grey Wire ) is reaching DPM's.

4.If DPM shows Dot Indication, check DPM IC7107. It might be Damaged.

19

Page 22
Image 22
B&K 1794 instruction manual No DPM Indication