( J ) POOR LOAD REGULATION.

POOR LOAD REGULATION

 

 

Load Terminal Nut inside Unit

 

 

might be Loose.

 

 

N

 

 

Is there any Oscillation

Y

Reduce Resistor R6 ( 2.2K ) on

in CV Mode ?

 

F/Panel PCB until Oscillation dies

N

 

OUT. If Oscillation still Prevail

 

reduce R9 to 2K on F/Panel PCB.

 

 

Is Capacitor C4 and C2 Leaky ?

 

 

Y

 

 

Replace It.

 

 

1.Load Terminal might be Loose. Ensure Terminals are tightened properly with Terminal Nuts inside the Unit.

2.There might be Oscillation at Output in CV Mode. Adjust Resistor R6 & R9 until Oscillations die out.

3.Check Capcitor C4 and C2 on PREG PCB. It might be Leaky.

( K ) CV, CC, LED NOT GLOW.

1.Check the LED's. it might be Leaky, Open or Short.