B&K 1794 instruction manual No Current Control, Poor Line Regulation, Preg PCB

Models: 1794

1 42
Download 42 pages 18.04 Kb
Page 26
Image 26

( H ) NO CURRENT CONTROL.

NO CURRENT CONTROL

Is Current Pot Open ?

Y

Replace it.

N

Are Wires related to Current Pot OK ?

Y

Ensure proper Connectivity.

1.Check the Current Potentiometer. It might be Open.

2.Check all Wires related to Current Potentiometer.

( I ) POOR LINE REGULATION.

POOR LINE REGULATION

 

 

 

Improper Device Drop Setting.

Y

Keep the Input Supply at rated I/P.

 

 

Keep the O/P Supply at rated Vtg.

N

 

and rated

Load. Measure Vtg.

 

 

across O/P

+Ve and Capacitor

Leaky Summing Capacitor C4.

 

+Ve Adjust that Vtg. between 4.5V

Y

 

to 5V with Preset VR1 ( 5K ) on

 

PREG PCB.

 

Replace It.

1.Check whether Device Drop is between 4.5V to 5V. It might not be proper.

2.Leaky Summing Capacitor C4 on PREG PCB.

23

Page 26
Image 26
B&K 1794 instruction manual No Current Control, Poor Line Regulation, Preg PCB