Baldor MN2410 manual Appendix a Premier K Series, Figure A-1 K3000 Operator Panel

Models: MN2410

1 60
Download 60 pages 30.4 Kb
Page 23
Image 23

Appendix A

Premier K Series

Information in this Appendix applies to the following Baldor Generators:

K3000, K5000, K5000E, K6500, K6500E

Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each receptacle is powered by a separate generator winding. When replacing a receptacle, inspect the brass tab that normally links both receptacles. If it is removed, be sure to remove the brass tab from the replacement receptacle before it is installed. Failure to remove the tab will cause a direct short to the generator windings and cause possible generator damage.

Operator Panel Configuration

Figure A-1 K3000 Operator Panel

120 VOLTS

 

 

DC

 

 

OUTPUT

120 VOLTS

 

 

AC VOLTMETER

DC POWER

CIRCUIT BREAKERS

ON

OFF

 

NEMA 5-15R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps. NEMA L5-30R Receptacle. Twist-lock style receptacle rated for 125VAC, 30 Amps.

DC Output.

12VDC output terminals for 12V loads.

AC Voltmeter.

This voltmeter displays the voltage level being produced by the generator set.

DC Power

Turns On/Off DC power at the DC Output terminals.

Hour Meter.

Displays the total run time hours of the generator set.

Circuit Breakers.

Provide overload protection for the generator set.

Figure A-2 K5000/K5000E/K6500/K6500E Operator Panel

NEMA 5-15R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.

120 VOLTS 120/240 VOLTS

DC

OUTPUT

120 VOLTS

AC VOLTMETER

AUTO IDLER

CIRCUIT BREAKERS

NEMA L5-30R Receptacle. Twist-lock style receptacle rated for 125VAC, 30 Amps. NEMA L14-30R Receptacle. Twist-lock style receptacle rated for 125/250VAC, 30 Am

DC Output.

12VDC output terminals for 12V loads.

AC Voltmeter.

This voltmeter displays the voltage level being produced by the generator set.

Auto Idler Switch.

ON - Auto idler is active, engine RPM will reduce when load is removed. OFF - Engine runs at fixed speed (set by governor).

DC ON - Auto Idler is Off and DC output terminals have power for 12V loads.

ONDC

OFF

Hour Meter.

Displays the total run time hours of the generator set.

Circuit Breakers.

Provide overload protection for the generator set.

MN2410

Premier K Series A-1

Page 23
Image 23
Baldor MN2410 manual Appendix a Premier K Series, Figure A-1 K3000 Operator Panel