Baldor MN2410 manual Appendix B Premier R Series, R30, R45, R45E, R60, R60E

Models: MN2410

1 60
Download 60 pages 30.4 Kb
Page 31
Image 31

Appendix B

Premier R Series

Information in this Appendix applies to the following Baldor Generators:

R30, R45, R45E, R60, R60E

Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each receptacle is powered by a separate generator winding. When replacing a receptacle, inspect the brass tab that normally links both receptacles. If it is removed, be sure to remove the brass tab from the replacement receptacle before it is installed. Failure to remove the tab will cause a direct short to the generator windings and cause possible generator damage.

Operator Panel Configuration

120 VOLTS

Figure B-1 R30 Operator Panel

NEMA 5-15R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.

Standard Duplex Receptacle. Standard household receptacle rated for 125VAC, 30 Amps.

When using this receptacle, ground fault protection is provided by the GFCI receptac

 

Hour Meter.

 

Displays the total run time hours of the generator set.

120 VOLTS

Auto Idler Switch.

ON - Auto idler is active, engine RPM will reduce when load is removed.

 

 

OFF - Engine runs at fixed speed (set by governor).

ELAPSED TIME

AC CIRCUIT BREAKER

AUTO IDLER

ONOFF

PUSH TO RESET

Circuit Breaker.

Provide overload protection for the generator set.

Figure B-2 R45/R45E/R60/R60E Operator Panel

AUTO IDLER

ON DC

ELAPSED

TIME

AC

VOLTMETER

AC CIRCUIT

BREAKERS

120 VOLTS

120 VOLTS

120/240 VOLTS

120 VOLTS

Auto Idler Switch.

ON - Auto idler is active, engine RPM will reduce when load is removed. OFF - Engine runs at fixed speed (set by governor).

Elapsed Time.

Displays the total run time hours of the generator set.

AC Voltmeter.

This voltmeter displays the voltage level being produced by the generator set.

AC Circuit Breakers.

Provide overload protection for the generator set.

120 Volts NEMA 5-15R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.

120 Volts NEMA L5-30R Receptacle.

Twist-lock style receptacle rated for 125VAC, 30 Amps.

120/240 Volts NEMA L14-30R Receptacle.

Twist-lock style receptacle rated for 125/250VAC, 30 Amps.

MN2410

Premier R Series B-1

Page 31
Image 31
Baldor MN2410 manual Appendix B Premier R Series, R30, R45, R45E, R60, R60E