Baldor MN2410 manual Appendix C Premier OHV Series, Figure C-1 OHV30 Operator Panel

Models: MN2410

1 60
Download 60 pages 30.4 Kb
Page 39
Image 39

Appendix C

Premier OHV Series

Information in this Appendix applies to the following Baldor Generators:

OHV30, OHV50, OHV60, OHV60E, OHV85E

Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each receptacle is powered by a separate generator winding. When replacing a receptacle, inspect the brass tab that normally links both receptacles. If it is removed, be sure to remove the brass tab from the replacement receptacle before it is installed. Failure to remove the tab will cause a direct short to the generator windings and cause possible generator damage.

Operator Panel Configuration

120 VOLTS

120 VOLTS

ELAPSED

AC CIRCUIT BREAKER

 

TIME

 

Figure C-1 OHV30 Operator Panel

NEMA 5-20R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 20 Amps.

Standard Duplex Receptacle. Standard household receptacle rated for 125VAC, 30 Amp When using this receptacle, ground fault protection is provided by the GFCI receptacle.

Hour Meter.

Displays the total run time hours of the generator set.

Circuit Breaker.

Provide overload protection for the generator set.

Figure C-2 OHV40/OHV50/OHV60/OHV60E Operator Panel

 

CIRCUIT

ELAPSED

CIRCUIT

 

 

TIME

 

BREAKER

 

BREAKER

 

 

 

 

 

 

AC

 

 

 

VOLTMETER

 

15 AMPS

30AMPS

 

 

15 AMPS 30AMPS

120 VOLTS

120 VOLTS

AUTO IDLER

120VOLTS 120/240VOLTS

 

 

 

 

 

ON

OFF

 

Circuit Breaker.

Provide overload protection for the generator set.

120 Volts NEMA 5-20R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 20 Amps.

120 Volts NEMA L5-30R Receptacle.

Twist-lock style receptacle rated for 125VAC, 30 Amps.

120/240 Volts NEMA L14-30R Receptacle.

Twist-lock style receptacle rated for 125/250VAC, 30 Amps.

AC Voltmeter. This voltmeter displays the voltage level being produced by the generator set. Elapsed Time. Displays the total run time hours of the generator set.

Auto Idler Switch. ON - Auto idler is active, engine RPM will reduce when load is removed. OFF - Engine runs at fixed speed (set by governor).

Figure C-3 OHV85E Operator Panel

AUTO IDLER

ON DC

ELAPSED

TIME

AC

VOLTMETER

AC CIRCUIT

BREAKERS

120 VOLTS

120 VOLTS

120/240 VOLTS

120 VOLTS

Auto Idler Switch.

ON - Auto idler is active, engine RPM will reduce when load is removed. OFF - Engine runs at fixed speed (set by governor).

DC ON - Auto Idler is Off and DC output terminals have power for 12V loads.

Elapsed Time.

Displays the total run time hours of the generator set.

AC Voltmeter.

This voltmeter displays the voltage level being produced by the generator set.

AC Circuit Breakers.

Provide overload protection for the generator set.

120 Volts NEMA 5-20R GFCI Receptacle.

This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.

120 Volts NEMA L5-30R Receptacle.

Twist-lock style receptacle rated for 125VAC, 30 Amps.

120/240 Volts NEMA L14-30R Receptacle.

Twist-lock style receptacle rated for 125/250VAC, 30 Amps.

MN2410

Premier OHV Series C-1

Page 39
Image 39
Baldor MN2410 manual Appendix C Premier OHV Series, Figure C-1 OHV30 Operator Panel