Hi RES Parameters Continued

Level 1, Input Setup Block Continued

Parameter

P#

Adjustable Range

Factory

User Setting

OP2 ANA IN1

1463

0-None, 1-(-10V to+10V),

1

 

TYPE

 

2-(-5V to+5V),

 

 

 

 

3-(4to20mA), 4-(0to20mA)

 

 

 

 

 

 

 

OP2 ANA IN1

1464

0-OFF, 1-ON

0

 

Invert

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1465

0.0% TO 300.0%

100.0

 

Gain

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1466

-100.0% TO 100.0%

0.0

 

Offset

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1467

0.0% TO 75.0%

0.0

 

Deadband

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1468

0 (No Filter) TO 6 (Max Filter)

0

 

Filter

 

 

 

 

 

 

 

 

 

OP2 ANA IN2

1469

0-None, 1-(-10V to+10V),

1

 

TYPE

 

2-(-5V to+5V),

 

 

 

 

3-(4to20mA), 4-(0to20mA)

 

 

OP2 ANA IN2

1470

0-OFF, 1-ON

0

 

Invert

 

 

 

 

 

 

 

 

 

OP2 ANA IN2

1471

0.0% TO 300.0%

100.0

 

Gain

 

 

 

 

 

 

 

 

 

OP2 ANA IN2

1472

-100.0% TO 100.0%

0.0

 

Offset

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1473

0.0% TO 75.0%

0.0

 

Deadband

 

 

 

 

 

 

 

 

 

OP2 ANA IN1

1474

0 (No Filter) TO 6 (Max Filter)

0

 

Filter

 

 

 

 

OP2 parameter selections (P#1463 to 1474) are available if the expansion board is installed in Slot2 of the Control.

Setup 4‐3

Page 17
Image 17
Baldor MN754 manual OP2 ANA IN1