Section 4

Software Setup

Overview

Programming setup is accomplished using the keypad of the control. General programming steps are defined in the appropriate control manual.

To install the expansion board see Section 3 of this manual.

1.Install EXBHH005 expansion board. If the board is in Slot 1, the OP1 inputs and outputs are used. If the board is in Slot 2, the OP2 inputs and outputs are used.

2.Set the Level 1 Input Setup block Command Source (P#1402) to select the desired analog input to use.

3.Refer to Figure 4‐1 and the Optional Analog Parameter tables and set the parameter values as desired for each input or output used.

Figure 4‐1 Relationship of Parameters

ANA In1+

 

 

 

2

 

 

 

 

 

 

ANA In1-

 

 

 

3

 

 

 

ANA In2+

 

 

 

4

 

 

 

 

ANA In2-

 

 

 

5

 

 

 

OPT DAC1

 

 

 

8

 

 

 

 

OPT DAC2

 

 

 

9

 

 

 

 

 

 

 

 

 

EXBHH005 HI RES Expansion Board

 

Type

 

 

 

 

 

 

 

 

 

 

To Control Bd.

 

 

 

 

 

 

 

 

Gain

Invert

Offset

 

 

 

 

 

 

 

Type

 

 

 

 

 

 

To Control Bd.

 

 

 

 

 

 

 

 

 

Gain

Invert

Offset

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

From Control Bd.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset Invert Gain

 

 

 

 

 

 

 

 

 

 

 

Type

 

From Control Bd.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Offset Invert Gain

 

 

 

Setup 4‐1

Page 15
Image 15
Baldor MN754 manual Section Software Setup, Overview, EXBHH005 HI RES Expansion Board