Baracoda 1500 Assembly, Flowkeeper Valve, For Pools With Return Inlet Directional Fittings

Models: 1500

1 12
Download 12 pages 52.15 Kb
Page 5
Image 5
FOR POOLS WITH RETURN INLET

Note: If the return inlets cannot be pointed downward, then you MUST install Zodiac return line diverters. Please call Zodiac for a dealer near you.

FOR POOLS WITH RETURN INLET

DIRECTIONAL FITTINGS

Replace the directional eyeball with Zodiac retrofit eyeball return line diverter and reinstall eyeball retaining ring.

Part #W90153 for 11/2" return lines

Part #W90155 for 2" return lines

IF UNABLE TO ADJUST RETURN INLETS

OR FOR POOLS WITHOUT RETURN

INLET DIRECTIONAL FITTINGS

Use Zodiac universal return line diverter (Part #W24100). Pinch wires together and insert fully into return inlet.

ASSEMBLY

Step 1: Slide the disc over the base of the footpad. Be sure it fits properly in the grooves provided. Be sure to install the disc with “TOP” printed facing up.

Step 2: Slide the wheel deflector onto the female end of the hose. The female end will eventually attach to the Zodiac 1500 head.

Female End

Wheel Deflector

Step 3: HOSE ASSEMBLY

SKIMMER

Assemble enough hose sections to reach

 

the farthest point in the pool from the

 

skimmer, plus one extra hose section.

 

Step 4: Place the hose protector sleeve over the male end of the hose. Place the hose connector on the male end of the hose.

HOSE

HOSE

FLOWKEEPER™

PROTECTOR NET

CONNECTOR

VALVE

MALE END

 

OF HOSE

 

FLOWKEEPER™ VALVE

The pool pump provides more gallon per minute flow than your Zodiac 1500

requires. That's why we provide a way to regulate the flow. The FlowKeeper Valve is IF UNABLE TO ADJUST RETURN INLETS self adjusting and provides a by-pass, so that the pool pump and the Zodiac 1500 run INLET DIRECTIONAL FITTINGSASSEMBLY properly. The FlowKeeper Valve MUST BE used.Step 3: HOSE ASSEMBLYFLOWKEEPER™ VALVEManual backgroundManual backgroundManual backgroundManual background

Skimming action is maintained through a bypass throat in the valve. As the filter collects debris, the valve automatically maintains the correct flow to the cleaner. The FlowKeeper valve comes preset at the two (2) setting. The lower the number, the lower the flow to the cleaner head. Should readjustment become necessary, pull the adjustment handle to raise or lower the setting. There are three total setting options.

To adjust setting, pull and move to desired setting.

5

Page 5
Image 5
Baracoda 1500 owner manual Flowkeeper Valve, For Pools With Return Inlet Directional Fittings, Hose Assembly