BaracodaPencil 2 – Communication Protocol v1.3 - 31 -
Data Capture for Workforce in Motion 2.4.6.2.2.4.6.2.2.4.6.2.2.4.6.2. SSSSet Configet Configet Configet Config ExaExaExaExample mple mple mple 2.1 2.1 2.1 2.1  Setting a configuration of Codabar symbology.Setting a configuration of Codabar symbology.Setting a configuration of Codabar symbology.Setting a configuration of Codabar symbology.
Frame to be sent to the decoder:
‘F’ ‘B’ 2 $03 , $01
Header
Type
Size
Command
Reading this frame, the decoder understands:
The user wants to set a configuration (Type "B") for Codabar (Header "F"). the configuration will
contain general options and others specific to cadabar (Size = 2). Then, the Command field contains
the configuration itself:
1
st
byte :
3
Bit
Option
1
0
Symbology Enabled
1
1
Min.
length
Enabled (set to 6 as defa
ult)
0
2
Checksum calculation
Disable
d
0
3
Checksum transmission Disable
d
0
4
M
ax
. length Disable
d
0
5
-
0
6
-
0
7
-
2
nd
byte :
1
Bit
Option
1
0
start
-
stop transmission
Enabled
0
1
-
0
2
-
0
3
-
0
4
-
0
5
-
0
6
-
0
7
-