BaracodaPencil 2 – Communication Protocol v1.3 - 28 -
Data Capture
for Workforce
in Motion
COMMANDS TABLE
Asci
i
CODE COMMAND RESPONDING HEADERS
A
Enable Symbology
All
B
Disable Symbology
All
Disable Min. length
A, B, C, E, F, G, H, J, K
D
Enable Min. length (1)
A, B, C, E, F, G, H, J, K
E
Enable Checksum calculation (2)
E, F, G, H, J, K
F
Disable Checksum
calculation (2)
E, F, G, H, J, K
G
Enable Checksum transmission
C, D, E, F, G, H, J, K, L, M,N,O
H
Disable Checksum transmission
C, D, E, F, G, H, J, K, L, M,N,O
I
Enable start/stop characters transmission
E, F
J
Disable start/stop characters transmiss
ion
E, F
K
Start/stop accepted characters "*" only
E
L
Start/stop accepted characters "$" only
E
M
start/stop accepted characters "*" and "$"
E
N
Enable Code 39 full ASCII mode
E
O
Disable Code 39 full ASCII mode
E
P
Enable number system transmission
D, L
Q
Disable number system transmission
D, L
R
Disable prefix
All
S
Enable
prefix
All
T
Disable suffix
All
U
Enable suffix
All
V
Enable ISBN and ISSN
D
W
Disable ISBN and ISSN
D
X
UPC
-
A/EAN 8 transmitted as EAN 13
D, M
Y
UPC
-
A/EAN 8 trans
mitted as UPC
-
A/EAN 8
D, M
Z
UPC
-
E transmitted as UPC
-
A
L
a
UPC
-
E transmitted as UPC
-
E
L
b
Enable hyphen transmission for ISSN
D
c
Dis
able hyphen transmission for ISSN
D
d
Disable Max. length
A, B, C, E, F, G, H, J, K
e
Enable Max. length (3)
A, B, C, E, F, G, H, J, K
f
Enable all EAN/UPC symbologies
D, L, M
g
Disable all EAN/UPC symbologies
D, L, M
i
Enable linkage flag transmission
N,O
j
Dissable linkage flag transmission
N,O
k
Enable application identifier transmission
N,O
l
Dissable applic
ation identifier transmission
N,O
m
Enable Group separator transmission (EAN128)
C
n
Dissable Group separator transmission (EAN128)
C