Data Capture for Workforce in Motion
| Command | Set page scan timeout | |
|
|
|
|
| Header | 0x24 |
|
|
|
| |
| Length | 00 04 | |
|
|
| |
| Payload | [Page Interval (MSB) Page Interval (LSB) Page Window (MSB) | |
|
| Page Window (LSB)] | |
|
| (default 0x320, 0xb0) | |
|
|
|
|
| Response | 0x24 | 00 01 01 if done |
|
| 0x24 | 00 01 00 if not |
|
|
| |
| Remark | Page Scan TimeOuts are used by the Module to answer to Connect | |
|
| Inquiries. So, if you set both values to 0, the Module will not be | |
|
| Connectable. | |
|
|
| |
|
|
| |
| Command | Get page scan timeout | |
|
|
|
|
| Header | 0x25 |
|
|
|
| |
| Length | 00 00 | |
| Payload |
|
|
|
|
| |
|
|
|
|
| Response | 0x25 | 00 04 [Page Interval (MSB) Page Interval (LSB) Page |
|
| Window (MSB) Page Window (LSB)] | |
|
|
| |
| Remark | Page Scan Interval and Page Scan Window are in number of | |
|
| Bluetooth slots) (1 slot = 0.625 ms) | |
|
|
|
|
Typical values are:
Full power:
Inquiry Interval = 0x400
Inquiry Window = 0x200
Page Scan Interval = 0x400
PageScan Window = 0x200
Low power:
Inquiry Interval = 0x320
Inquiry Window = 0x80
Page Scan Interval = 0x320
PageScan Window = 0x80
Here is how these values change the consumption of the Module:
Page Scan
Window
Inquiry Scan
Window
Page Scan and Inquiry Scan Interval
BaracodaPencil 2 – Communication Protocol v1.3 | - 37 - |