Configuration Option Tables

System Options Menu

For System Options, refer to Table A-3. To access the System Options screen, follow this menu selection sequence:

Main Menu Configuration Load Configuration From

main/config/system

Hotwire

 

Model: 7984

SYSTEM OPTIONS

 

DSL Mode:

NTU

Test Timeout:

Enable

Test Duration (min):

10

Telco Initiated Loopback:

Enable

Remote Telco Line Loopback:

Disable

±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

Table A-3. System Options (1 of 2)

DSL Mode

Possible Settings: LTU, NTU

Default Setting: NTU

Controls whether the unit is configured as a control unit or tributary unit.

LTU ± The unit is configured as a control unit (Line Termination Unit).

NTU ± The unit is configured as a tributary unit (Network Termination Unit). This unit will request its IP address from the LTU during establishment of the PPP link.

NOTE: Changing this option will reset the card.

Test Timeout

Possible Settings: Enable, Disable

Default Setting: Enable

Allows tests to end automatically. The feature should be enabled when the unit is remotely managed, so that control can be regained after a test is accidentally executed.

Enable ± Loopback and pattern tests end when test duration is reached.

Disable ± Tests run until manually terminated from the Network Tests screen or remotely (network initiated tests). Refer to Running Network Tests in Chapter 5, Testing.

Test Duration (min)

Possible Settings: 1±120

Default Setting: 10

Number of minutes for a test to be active before automatically ending.

HTest Duration (min) appears when Test Timeout is enabled.

1 to 120 ± Amount of time in minutes for a test runs before terminating.