Paradyne Hotwire 7984 manual General SNMP Management Options, A-16

Models: Hotwire 7984

1 122
Download 122 pages 48.4 Kb
Page 96
Image 96
General SNMP Management Options

Configuration Option Tables

General SNMP Management Options

SNMP configuration options allow you to specify the information necessary to support the Termination Unit General SNMP functionality. To access the General SNMP Management Options screen, follow this menu selection sequence:

Main Menu Configuration Load Configuration From Edit

Management and Communication SNMP General SNMP Management

main/config/management/SNMP

Hotwire

Slot: 4

 

 

 

Model: 7984

 

GENERAL SNMP MANAGEMENT OPTIONS

 

SNMP Management:

Enable

 

Community Name 1:

Public

 

 

 

Name 1 Access:

Read/Write

 

Community Name 2:

Public

 

 

 

Name 2 Access:

Read/Write

 

±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±±

Ctrl-a to access these functions, ESC for previous menu MainMenu Exit Save

Table A-7. General SNMP Management Options (1 of 2)

SNMP Management

Possible Settings: Enable, Disable

Default Setting: Disable

Enables or disables the SNMP management features.

Enable ± Enables SNMP management capabilities.

Disable ± Disables SNMP management capabilities.

Community Name 1

Possible Settings: ASCII text field, Public

Default Text: Public

Identifies the name of the community allowed to access the unit's MIB. The community name must be supplied by an external SNMP manager when that manager attempts to access an object in the MIB.

Text Field ± Enter or edit a community name.

Clear ± Clears the community name field.

A-16

February 1999

7984-A2-GB20-10

Page 96
Image 96
Paradyne Hotwire 7984 General SNMP Management Options, A-16, Management and Communication → SNMP → General SNMP Management