Monitoring the Unit

HStatus: Contains the contents of the status events register. The status events register maintains a history of specific events that have occurred during an interval. Values include:

ÐY ± Remote alarm indication signal (yellow alarm) received at the DSX-1 interface

ÐL ± Loss of signal detected at the DSX-1 interface

ÐE ± Excessive error rate threshold exceeded

ÐF ± Frame synchronization bit error detected

ÐV ± Line code violation detected

ÐNone ± No significant events have occurred

This Field . . .

Contains . . .

 

 

Current Interval

The number of seconds which have elapsed in the current

Timer

15-minute interval. Maximum value is 900 seconds (15 minutes).

 

This counter resets every 15 minutes.

 

 

Current Interval

Performance data for the current 15 minutes.

 

 

Interval xx

Historical performance data for up to 96 15-minute intervals

 

(24 hours) where the value of xx is from 01 to 96.

 

 

Error Events

A running total of CRC and OOF events. Total range = 0±65535.

Counter

Counter resets when the statistics are cleared.

 

 