Initial Startup and Configuration

Configuring the Unit Using the Internal Switches

Use internal Switchpacks S1 and S2 to manually configure the unit. Use

Figure 3-1to locate Switchpacks S1 and S2.

!HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES

 

This product is designed to protect sensitive components from damage

 

due to electrostatic discharge (ESD) during normal operation. When

 

performing installation procedures, however, take proper static control

 

precautions to prevent damage to equipment. If you are not sure of the

496-15104

proper static control precautions, contact your nearest sales or service

representative.

 

"Procedure

To configure the unit using internal Switchpacks S1 and S2:

1.Power down the unit and remove the enclosure cover, exposing the circuit board.

2.Locate Switchpack S1 using Figure 3-1.

3.Set Switch 1 on Switchpack S1 to ON to enable Switchpacks 1 and 2.

4.After you enable the switchpacks, you must set the switches to your desired configuration. Refer to Figure 3-1and Table 3-1.

5.Replace and secure the cover.

6.Power up the board to reset and enable the new configuration.