Paradyne Hotwire 7984 1. Health and Status Messages 1 of, What Message Indicates, What To Do

Models: Hotwire 7984

1 122
Download 122 pages 48.4 Kb
Page 45
Image 45
Health and Status

Monitoring the Unit

Health and Status

The following messages can appear in the first column of the System and Test Status screen. The highest priority Health and Status message also appears on all ATI screens on the bottom right.

Table 4-1. Health and Status Messages (1 of 2)

Message

What Message Indicates

What To Do

System Operational

There are no problems

 

 

 

detected.

 

 

 

 

 

 

LOS at Net, Pt 1

An LOS (Loss Of Signal)

1.

Verify that the network cable is

 

condition has been

 

securely attached at both ends.

 

detected on the network

2.

Verify proper NTU and LTU

 

interface. No signal is

 

 

configuration

 

being received on Port 1,

 

 

 

 

 

possibly due to a local

3.

Contact network provider.

 

network problem.

 

 

 

 

 

OOF at Net, Pt 1

An OOF (Out Of Frame)

Contact network provider.

 

condition has been

 

 

 

detected at the network

 

 

 

interface.

 

 

 

 

 

 

LOS at DSX-1, Pt 1

An LOS (Loss Of Signal)

1.

Verify proper framing.

 

condition has been

2.

Contact network provider.

 

detected on the DSX-1

 

 

 

 

interface.

 

 

 

 

 

NTU/LTU Mis match,

The NTU is not configured

Configure units to match.

Pt 1

the same as the LTU.

 

 

 

 

 

 

LOF at DSX-1, Pt 1

An LOF (Loss Of Frame)

1.

Verify that the network cable is

 

condition has been

 

securely attached at both ends.

 

detected on the DSX-1

2.

Contact network provider.

 

interface.

 

 

 

 

 

 

 

AIS at DSX-1, Pt 1

An Alarm Indication Signal (AIS) is being received by the DSX-1 interface.

1.Verify that the units line framing and line coding are compatible.

2.Contact network provider.

EER at Net, Pt 1

An EER (Excessive Error Rate) condition has been detected on the network interface at Port 1. The condition is cleared when the error rate falls below the threshold value currently configured.

1.Ignore condition if 511 test active.

2.Contact network provider.

EER at DSX-1, Pt 1

An EER (Excessive Error Rate) condition has been detected on the DSX-1 interface.

1.Verify the attached equipment coding is compatible.

2.Contact network provider.

Yellow alarm at

A Yellow Alarm Indication

1.

Verify that the units line framing

DSX-1, Pt 1

signal is being received by

 

and line coding are compatible.

 

the DSX-1 interface.

2.

Contact network provider.

 

 

 

 

 

 

7984-A2-GB20-10

February 1999

4-3

Page 45
Image 45
Paradyne Hotwire 7984 manual 1. Health and Status Messages 1 of, What Message Indicates, What To Do