Paradyne Hotwire 7984 manual linkUp and linkDown, linkUp/Down Variable-Bindings

Models: Hotwire 7984

1 122
Download 122 pages 48.4 Kb
Page 104
Image 104
linkUp and linkDown

Standards Compliance for SNMP Traps

linkUp and linkDown

The link SNMP traps are:

HlinkUp ± The unit recognizes that one of the communication interfaces is operational.

HlinkDown ± The unit recognizes that one of the communication interfaces is not operational.

The network and synchronous port interfaces (physical sublayer) are represented by an entry in the MIB-II interfaces table and supported by the DS1 MIB.

The following list describes the conditions that define linkUp and linkDown:

linkUp/Down Variable-Bindings

HifIndex (RFC 1573)

This object provides the index into the ifTable and potentially into tables in other MIBs. The values of ifIndex are the same for all models, although not all indexes are supported for each model.

The ifIndex included with the trap consists of:

±1 COM Port

±2 HDSL Network Interface, Port 1

±6 DSX-1 Interface, Port 1

HifAdminStatus (RFC 1573)

This object specifies the operational state of the interface:

±up(1)

HDSL Network: DSL link is established.

DSX-1: No alarm condition exists.

±down(2)

HDSL Network: DSL link is not established.

DSX-1: An alarm condition exists.

±testing(3)

A test is active on the interface.

HifOperStatus (RFC 1573)

This object contains the same value as ifAdminStatus.

HifType (RFC 1573)

This object is the type of interface:

±T1(19)

Used for the DSX-1 interface.

B-2

February 1999

7984-A2-GB20-10

Page 104