Table 4-1. Health and Status Messages (2 of 2)

Monitoring the Unit

Table 4-1. Health and Status Messages (2 of 2)

Message

What Message Indicates

What To Do

 

 

 

 

Net Margin

The signal-to-noise margin

1.

Reconfigure the unit to a higher

Threshold, Pt 1

has exceeded the

 

Net Margin Threshold.

 

configured threshold.

2.

Contact network provider.

 

 

 

 

 

 

Primary Clock Failed

A failure has occurred in

1.

Verify that the network cable is

(DSX-1, Pt 1)

the primary clock source

 

securely attached at both ends.

 

configured from the

2.

Contact network provider.

 

Network, DSX, or from the

 

 

 

 

card internal clock.

 

 

 

 

 

 

DeviceFailed

An internal error has been

1.

Provide the 8-digit failure code

yyyyyyyy

detected by the operating

 

shown ( yyyyyyyy ) to your service

 

software. yyyyyyyy

 

representative.

 

indicates the 8-digit

2.

Reset the 7984 Standalone

 

hexadecimal failure code.

 

 

Termination Unit to clear the

 

 

 

 

 

 

condition and message.

 

 

 

Download Failed

A firmware download was

Repeat the download.

 

interrupted.

 

 

 

 

 

 

Net Com Link Down

The Network

1.

Verify that the network cable is

 

communication link is

 

securely attached at both ends.

 

down. Communications

2.

Verify the link protocol for the

 

between the management

 

 

COM port is configured correctly.

 

system and the LTU/NTU

 

 

 

 

 

is not possible.

 

 

 

 

 

 