Troubleshooting

Messages and Troubleshooting

Troubleshooting

This 7984 Standalone Termination Unit is designed to provide you with many years of trouble-free service. If a problem occurs, however, refer to

Table 6-2 for possible solutions.

Table 6-2. Troubleshooting (1 of 2)

Symptom

Possible Cause

Solutions

 

 

 

Alarm LED is on.

One of several alarm

Refer to Table 4-1,Health and Status

 

conditions exists. Health

Messages, in Chapter 4, Monitoring

 

and Status displays the

the Unit, for a recommended action.

 

alarm condition.

 

 

 

 

Cannot access the

The terminal is not set up

H Check the cable and connections.

unit via the ATI.

for the correct rate or data

H Ensure the unit is configured

 

format, or the unit is

 

properly. Verify IP address and

 

configured so it prevents

 

communication port usage.

 

access.

 

 

 

 

H Reset the unit.

 

 

 

Device Fail appears

The unit detects an internal

H Reset the unit.

on the System and

hardware failure.

H Contact your service

Test Status screen

 

 

representative.

under Self-Test

 

 

 

results.

 

 

 

 

 

No power, or the

The power cord is not

Check that the power cord is

LEDs are not lit.

securely plugged into the

securely attached at both ends.

 

wall receptacle and into the

 

 

rear panel connection.

 

 

 

 

 

The wall receptacle has no

H Check the wall receptacle power

 

power.

by plugging in some equipment

 

 

that is known to be working.

 

 

H Check the power switch on the

 

 

units rear panel.

 

 

H Check the circuit breaker.

 

 

H Verify that your site is not on an

 

 

energy management program.

 

 

 

 

Power supply has failed.

Replace power supply.

 

 

 

An LED is not lit.

LED is out.

Run the Lamp test. If the LED in

 

 

question does not flash with the other

 

 

LEDs, then contact your service

 

 

representative.

 

 

 