2.5Troubleshooting

If a power failure occurs...

Your system enables a conversation between a specific outside (CO) line and extension (Power Failure Transfer) and supports system data backup.

Power Failure Transfer

A specific extension can be automatically connected to a specific outside (CO) line. This provides outside (CO) line calls between the following extension and outside (CO) line.

Outside (CO) line 1 is connected to extension jack 01.

Outside (CO) line 4 is connected to extension jack 09.

All other conversations will be disconnected during a power failure.

Proprietary telephones (PT) cannot be used during a power failure. A single line telephone will work in the event of a power failure. Connect the single line telephone to the above jack.

When power is restored after a power failure, your system automatically restarts, maintaining as much of the previous system data as possible.

 

Problem

 

Probable Cause

Possible Solution

 

 

 

 

 

Nothing is heard in the

 

“HEADSET” is selected.

Set the “HANDSET/HEADSET”

handsfree mode.

 

 

Selector to “HANDSET” on the back of

 

 

 

 

the KX-T7330.

 

 

 

 

The unit does not ring.

 

• An outside (CO) line

• To program outside (CO) line numbers,

 

 

 

number is not programmed.

refer to the Installation Manual.

 

 

 

• The Ringer Volume is set

• Increase the Ringer Volume. Refer to

 

 

 

to “OFF”.

“Volume Control” in Proprietary

 

 

 

 

Telephone Settings.

 

 

 

 

The display flashes the

 

The system internal clock is

Consult with an authorized Panasonic

following message.

 

not working properly.

Factory Service Center.

 

 

 

 

 

 

Set Time & Date

 

 

 

 

 

 

 

 

Appendix

Appendix 2-11

Page 121
Image 121
Panasonic KX-TA308 operating instructions Troubleshooting, If a power failure occurs, Power Failure Transfer