Data Capture

for Workforce

in Motion

5.2 Caps Lock function

The USB Plug & Scan dongle can disable the CAPS LOCK key on the HOST.

Force Caps lock OFF : enabled

<: ? > ' \ N U L \ S O H \ S O H Force Caps lock OFF : disabled(*)

<: ? > ' \ N U L \ S O H \ N U L

Note: This feature is disabled by default.

5.3 Keyboard emulation speed

The barcode upload process can stress the host and, depending on the host type, the below barcodes may be necessary.

Indeed, the USB Plug&Scan dongle emulates a Keyboard. Thus, it has to send characters with a minor delay between them. If the delay is too short or if the host is too slow or too busy to process the incoming characters, some data can be lost by the host.

To avoid that phenomenon, the USB Plug&Scan can handle different keyboard emulation speeds:

Keyboard emulation speed: SLOW

Keyboard emulation speed: VERY SLOW

Inter-character delay = 40ms

Inter-character delay = 80ms

Keyboard emulation speed: SLOW

Keyboard emulation speed: MEDIUM (*)

Inter-character delay = 20ms

Inter-character delay = 16ms

Keyboard emulation speed: HIGH

Inter-character delay = 8ms

Baracoda USB Plug & Scan dongle – User Guide v3.33b