TABLE 5
Electrical Specifications — W**L Series
|
|
|
| Single Circuit |
|
|
|
| Dual Circuit |
|
|
| |||
| Rated | No. Field | 3 Minimum | 1 Maximum | 2 Field |
| 3 Minimum | 1 Maximum | 2 Field | 2 Ground | |||||
| 2 Ground | Circuit | External Fuse | Power | |||||||||||
Model | Volts | Power | Circuit | External Fuse | Power | Wire Size | |||||||||
Wire | Ampacity | or Ckt. Brkr. | Wire Size | ||||||||||||
| and Phase | Circuits | Ampacity | or Ckt. Brkr. | Wire Size |
|
| ||||||||
|
|
|
|
|
|
| Ckt. A | Ckt. B | Ckt. A | Ckt. B | Ckt. A | Ckt. B | Ckt. A | Ckt. B | |
W18L1 - A00, A0Z |
| 1 | 16 | 20 | 12 | 12 |
|
|
|
|
|
|
|
| |
A05 | 1 | 30 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| ||
A08 | 1 | 46 | 50 | 8 | 10 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||||||
A10 |
| 1 | 56 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| |
W24L1 - A00, A0Z |
| 1 | 21 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| |
A05 | 1 | 30 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| ||
A08 | 1 | 46 | 50 | 8 | 10 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||||||
A10 |
| 1 | 56 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| |
W24L1 - B00, B0Z | 1 | 15 | 15 | 14 | 14 |
|
|
|
|
|
|
|
| ||
B06 | 1 | 22 | 25 | 10 | 10 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||||||
W30L1 - A00*, A0Z* |
| 1 | 24 | 35 | 8 | 10 |
|
|
|
|
|
|
|
| |
A05* |
| 1 | 32 | 35 | 8 | 10 |
|
|
|
|
|
|
|
| |
A08 | 1 | 48 | 50 | 8 | 10 |
|
|
|
|
|
|
|
| ||
A10* |
| 1 | 58 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| |
A15 |
| 1 or 2 | 84 | 90 | 4 | 8 | 58 | 26 | 60 | 30 | 6 | 10 | 10 | 10 | |
W30L1 - B00*, B0Z* |
| 1 | 18 | 20 | 12 | 12 |
|
|
|
|
|
|
|
| |
B09* | 1 | 33 | 35 | 8 | 10 |
|
|
|
|
|
|
|
| ||
B15 |
| 1 | 51 | 60 | 8 | 10 |
|
|
|
|
|
|
|
| |
W30L1 - C00*, C0Z* |
| 1 | 11 | 15 | 14 | 14 |
|
|
|
|
|
|
|
| |
C09* | 1 | 17 | 20 | 12 | 12 |
|
|
|
|
|
|
|
| ||
C15 |
| 1 | 26 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| |
W36L1 - A00*, A0Z* |
| 1 | 29 | 35 | 8 | 10 |
|
|
|
|
|
|
|
| |
A05* | 1 | 32 | 35 | 8 | 10 |
|
|
|
|
|
|
|
| ||
A10* | 1 | 58 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||||||
A15 |
| 1 or 2 | 84 | 90 | 4 | 8 | 58 | 26 | 60 | 30 | 6 | 10 | 10 | 10 | |
W36L1 - B00*, B0Z* |
| 1 | 23 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| |
B09* | 1 | 33 | 35 | 8 | 10 |
|
|
|
|
|
|
|
| ||
B15 |
| 1 | 51 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| |
W36L1 - C00*, C0Z* |
| 1 | 12 | 15 | 14 | 14 |
|
|
|
|
|
|
|
| |
C09* | 1 | 17 | 20 | 10 | 10 |
|
|
|
|
|
|
|
| ||
C15 |
| 1 | 26 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| |
W42L1 - A00, A0Z |
| 1 | 33 | 50 | 8 | 10 |
|
|
|
|
|
|
|
| |
A05 | 1 | 33 | 50 | 8 | 10 |
|
|
|
|
|
|
|
| ||
A10 | 1 | 59 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||||||
A15 |
| 1 or 2 | 85 | 90 | 4 | 8 | 59 | 26 | 60 | 30 | 6 | 10 | 10 | 10 | |
W42L1 - B00, B0Z |
| 1 | 25 | 35 | 8 | 10 |
|
|
|
|
|
|
|
| |
B09 | 1 | 34 | 35 | 8 | 10 |
|
|
|
|
|
|
|
| ||
B15 |
| 1 | 53 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| |
W42L1 - C00, C0Z |
| 1 | 13 | 15 | 14 | 14 |
|
|
|
|
|
|
|
| |
C09 | 1 | 18 | 20 | 12 | 12 |
|
|
|
|
|
|
|
| ||
C15 |
| 1 | 27 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| |
W48L1 - A00, A0Z |
| 1 | 37 | 50 | 8 | 10 |
|
|
|
|
|
|
|
| |
A05 | 1 | 37 | 50 | 8 | 10 |
|
|
|
|
|
|
|
| ||
A10 | 1 | 59 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||||||
A15 |
| 1 or 2 | 85 | 90 | 4 | 8 | 59 | 26 | 60 | 30 | 6 | 10 | 10 | 10 | |
W48L1- B00, B0Z |
| 1 | 29 | 40 | 8 | 10 |
|
|
|
|
|
|
|
| |
B09 | 1 | 34 | 40 | 8 | 10 |
|
|
|
|
|
|
|
| ||
B15 |
| 1 | 52 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| |
W48L1 - C00, C0Z |
| 1 | 14 | 20 | 12 | 12 |
|
|
|
|
|
|
|
| |
C09 | 1 | 18 | 20 | 12 | 12 |
|
|
|
|
|
|
|
| ||
C15 |
| 1 | 27 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| |
W60L1 - A00, A0Z |
| 1 | 41 | 60 | 8 | 10 |
|
|
|
|
|
|
|
| |
A05 | 1 | 41 | 60 | 8 | 10 |
|
|
|
|
|
|
|
| ||
A10 | 1 | 59 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||||||
A15 |
| 1 or 2 | 85 | 90 | 4 | 8 | 59 | 26 | 60 | 30 | 6 | 10 | 10 | 10 | |
W60L1 - B00, B0Z |
| 1 | 28 | 40 | 8 | 10 |
|
|
|
|
|
|
|
| |
B09 | 1 | 34 | 40 | 8 | 10 |
|
|
|
|
|
|
|
| ||
B15 |
| 1 | 53 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| |
W60L1 - C00, C0Z |
| 1 | 15 | 20 | 12 | 12 |
|
|
|
|
|
|
|
| |
C09 | 1 | 18 | 20 | 12 | 12 |
|
|
|
|
|
|
|
| ||
C15 |
| 1 | 27 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| |
W70L1 - A0Z |
| 1 | 49 | 60 | 8 | 10 |
|
|
|
|
|
|
|
| |
A05 | 1 | 49 | 60 | 8 | 10 |
|
|
|
|
|
|
|
| ||
A10 | 1 or 2 | 59 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |||||||
A15 |
| 1 or 2 | 85 | 90 | 4 | 8 | 59 | 26 | 60 | 30 | 6 | 10 | 10 | 10 | |
W70L1 - B0Z |
| 1 | 43 | 60 | 8 | 10 |
|
|
|
|
|
|
|
| |
B09 | 1 | 43 | 60 | 8 | 10 |
|
|
|
|
|
|
|
| ||
B15 |
| 1 | 53 | 60 | 6 | 10 |
|
|
|
|
|
|
|
| |
W70L1 - C0Z |
| 1 | 23 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| |
C09 | 1 | 23 | 30 | 10 | 10 |
|
|
|
|
|
|
|
| ||
C15 |
| 1 | 27 | 35 | 8 | 10 |
|
|
|
|
|
|
|
|
1Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors.
2 Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codes.
3 These “Minimum Circuit Ampacity” values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor sizing.
Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway.