TABLE 6

RECOMMENDED AIRFLOW

 

Rated

Rated

Recommended

Factory Speed

Model

CFM *

ESP *

Airflow Range

Connection

 

 

 

 

 

 

W18A, W18L

550

.40

575

- 725

High

 

 

 

 

 

 

W24A, W24L

800

.20

700

- 950

High

 

 

 

 

 

W30A, W30L

1000

.40

930 - 1300

High

 

 

 

 

 

W36A, W36L

1100

.30

930 - 1350

High

 

 

 

 

 

W42A, W42L

1400

.30

1600 - 1150

High

 

 

 

 

 

 

W48A, W48L

1550

.20

1750

- 1285

High

 

 

 

 

 

 

W60A, W60L

1650

.30

1950

- 1375

High

 

 

 

 

 

 

W70A, W70L

1800

.20

2000

- 1475

High

 

 

 

 

 

 

* Rated CFM and ESP on high speed tap.

TABLE 7

INDOOR BLOWER PERFORMANCE

 

W18A/L,

 

W30A/L, W36A/L

 

 

W42A/L, W48A/L

 

 

W60A/L, W70A/L

 

 

W24A/L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E.S.P.

High Speed

High Speed

Low Speed

High Speed

Low Speed

High Speed

Low Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

In

Dry

Wet

Dry

 

Wet

Dry

 

Wet

Dry

 

Wet

Dry

 

Wet

Dry

 

Wet

Dry

 

Wet

H2O

Coil

Coil

Coil

 

Coil

Coil

 

Coil

Coil

 

Coil

Coil

 

Coil

Coil

 

Coil

Coil

 

Coil

.0

1020

975

1395

 

1315

950

 

935

1885

 

1800

1650

 

1600

2200

 

2000

1600

 

1450

.1

960

905

1340

 

1270

930

 

915

1770

 

1665

1550

 

1500

2100

 

1900

1525

 

1375

.2

865

800

1285

 

1190

910

 

885

1635

 

1540

1450

 

1400

2000

 

1800

 

.3

820

735

1205

 

1100

855

 

830

1500

 

1400

1350

 

1300

1875

 

1700

 

.4

735

650

1110

 

1000

800

 

755

1370

 

1285

1300

 

1175

1775

 

1600

 

.5

615

535

1005

 

870

 

1250

 

1150

 

1650

 

1475

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TABLE 8

MAXIMUM ESP OF OPERATION

ELECTRIC HEAT ONLY

 

Model

W18A/L, W24A/L

 

W30A/L, W36A/L

 

W42A/L, W48A/L

W60A/L, W70A/L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet

FRONT

FRONT

TOP

FRONT

FRONT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

Single

High

Low

High

 

Low

High

Low

High

Low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-A0Z

.50

.50

.50

.50

 

.50

.50

.50

.50

.50

 

 

-A04

 

 

 

.50

 

.45

 

 

 

 

 

 

-A05

.50

.50

.50

 

 

 

.50

.50

.50

.50

 

 

-A08

.50

.50

.50

 

 

 

 

 

 

 

 

 

-A10

 

.50

.45

.50

 

.35

.50

.50

.50

.50

 

 

-A15

 

.40

.35

 

 

 

.50

.50

.50

.50

 

 

-A20

 

 

 

 

 

 

.50

.45

.50

.40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-B0Z

.50

.50

.50

.50

 

.50

.50

.50

.50

.50

 

 

-B06

.50

.50

.40

 

 

 

 

 

 

 

 

 

-B09

 

.50

.50

.45

 

.40

.50

.50

.50

.50

 

 

-B15

 

.45

.30

 

 

 

.50

.50

.50

.50

 

 

-B18

 

 

 

 

 

 

.50

.50

.50

.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-C0Z

 

.50

.50

.50

 

.50

.50

.50

.50

.50

 

 

-C06

 

.50

.50

 

 

 

 

 

 

 

 

 

-C09

 

.50

.40

.45

 

.40

.50

.50

.50

.50

 

 

-C15

 

.45

.35

 

 

 

.50

.50

.50

.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Values shown are for units equipped with standard 1-inch throwaway filter or 1-inch washable filter.

 