Symptom-to-FRU index
This section contains following information:
•“Numeric error codes” on page 43
•“Error messages” on page 45
•“Beep symptoms” on page 46
•
•
•“Intermittent problems” on page 48
•“Undetermined problems” on page 48
The
Note: Do the FRU replacement or other actions in the sequence shown in the column headed “FRU or action, in sequence.” If replacing a FRU does not solve the problem, put the original part back in the computer. Do not replace a nondefective FRU.
This index can also help you determine, during regular servicing, what FRUs are likely to need to be replaced next.
A numeric error is displayed for each error detected in POST or system operation. In the displays, n can be any number.
If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not described there, go to “Intermittent problems” on page 48.
Note: For a device not supported by diagnostic codes in the ThinkPad Notebooks, see the manual for that device.
Numeric error codes
Table 2. Numeric error codes
Symptom or error | FRU or action, in sequence | |
|
| |
0177 | System board. | |
Bad SVP data, stop POST |
|
|
supervisor password in the EEPROM is not correct. |
|
|
|
|
|
0182 | 1. | Run the ThinkPad Setup program. Press F9, and |
Bad CRC2. Enter the ThinkPad Setup program and load |
| Enter to load the default setting. Then save the |
Setup |
| current setting by pressing F10. |
the EEPROM is not correct. | 2. System board. | |
|
|
|
0183 |
|
|
Bad CRC of Security Settings in EFI Variable. Enter the |
|
|
ThinkPad Setup program. |
|
|
|
| |
0187 | System board. | |
EAIA data access |
|
|
|
| |
0188 | System board. | |
Invalid RFID Serialization Information Area. |
|
|
|
| |
0189 | System board. | |
Invalid RFID configuration information |
|
|
EEPROM checksum is not correct. |
|
|
|
|
|
0190 | 1. | Charge the battery pack. |
Critical | 2. | Battery pack. |
|
|
|
Chapter 4. Related service information 43