Technical Reference Guide

A.19 SCSI INTERFACE ERROR MESSAGES (65xx-xx, 66xx-xx, 67xx-xx)

Table A–18.SCSI Interface Error Messages

Table A-18.

SCSI Interface Error Messages

Message

Probable Cause

 

Message

Probable Cause

6nyy-02

Drive not installed

 

6nyy-33

Illegal controller command

6nyy-03

Media not installed

 

6nyy-34

Invalid SCSI bus phase

6nyy-05

Seek failure

 

 

6nyy-35

Invalid SCSI bus phase

6nyy-06

Drive timed out

 

 

6nyy-36

Invalid SCSI bus phase

6nyy-07

Drive busy

 

 

6nyy-39

Error status from drive

6nyy-08

Drive already reserved

 

6nyy-40

Drive timed out

6nyy-09

Reserved

 

 

6nyy-41

SSI bus stayed busy

6nyy-10

Reserved

 

 

6nyy-42

ACK/REQ lines bad

6nyy-11

Media soft error

 

 

6nyy-43

ACK did not deassert

6nyy-12

Drive not ready

 

 

6nyy-44

Parity error

6nyy-13

Media error

 

 

6nyy-50

Data pins bad

6nyy-14

Drive hardware error

 

6nyy-51

Data line 7 bad

6nyy-15

Illegal drive command

 

6nyy-52

MSG, C/D, or I/O lines bad

6nyy-16

Media was changed

 

6nyy-53

BSY never went busy

6nyy-17

Tape write-protected

 

6nyy-54

BSY stayed busy

6nyy-18

No data detected

 

6nyy-60

Controller CONFIG-1 register fault

6nyy-21

Drive command aborted

 

6nyy-61

Controller CONFIG-2 register fault

6nyy-24

Media hard error

 

6nyy-65

Media not unloaded

6nyy-25

Reserved

 

 

6nyy-90

Fan failure

6nyy-30

Controller timed out

 

6nyy-91

Over temperature condition

6nyy-31

Unrecoverable error

 

6nyy-92

Side panel not installed

6nyy-32

Controller/drive not connected

 

6nyy-99

Autoloader reported tape not loaded properly

n = 5, Hard drive

yy = 00, ID

 

 

 

= 6, CD-ROM drive

= 03, Power check

 

 

= 7, Tape drive.

= 05, Read

 

 

 

 

= 06, SA/Media

 

 

 

 

= 08, Controller

 

 

 

 

= 23, Random read

 

 

 

= 28, Media load/unload

 

A.20 POINTING DEVICE INTERFACE ERROR MESSAGES (8601-xx)

Table A–19.Pointing Device Interface Error Messages

Table A-19.

Pointing Device Interface Error Messages

Message

Probable Cause

Message

Probable Cause

8601-01

Mouse ID fails

8601-07

Right block not selected

8601-02

Left mouse button is inoperative

8601-08

Timeout occurred

8601-03

Left mouse button is stuck closed

8601-09

Mouse loopback test failed

8601-04

Right mouse button is inoperative

8601-10

Pointing device is inoperative

8601-05

Right mouse button is stuck closed

8602-xx

I/F test failed

8601-06

Left block not selected

--

--

Compaq Personal Computers A-11

Changed – November 2000

Page 173
Image 173
Compaq 850 manual Scsi Interface Error Messages 65xx-xx, 66xx-xx, Pointing Device Interface Error Messages, Table A-18