See specific wiring information for the different models, heater KWs, and voltages.

TABLE 7

HEAT PUMP THERMOSTATS

THERMOSTAT

SUBBASE

 

DESCRIPTION

 

 

 

 

 

8403-045

Part of

1 stage cool, 2 stage heat; Mecury bulb; Manual changeover

 

Fan Switch: Auto-On;

System Switch: Em Heat-Heat-Off-Cool

 

(T841A1761)

Thermostat

 

Indicating Lamps: Check-Em Heat-Aux Heat

 

 

 

 

 

 

 

 

8403-017

8404-009

1 stage cool, 2 stage heat; Mercury bulb; Manual changeover

Q

Fan Switch: Auto-On;

System Switch: Em Heat-Heat-Off-Cool

(T874R1129)

Q674L1181

Indicating Lamps: Check-Em Heat

 

 

 

 

 

 

 

 

8403-018

8404-010

1 stage cool, 2 stage heat; Mercury bulb; Auto changeover

 

Fan Switch: Auto-On;

System Switch: Off-Em Heat-Heat-Auto-Cool

R

(T874N1024)

Q674F1261

Indicating Lamps: Check-Em Heat

 

 

 

 

 

 

 

 

 

1 stage cool, 2 stage heat; Digital non-programmable (no battery required)

8403-042

Part of

Automatic or manual changeover

 

(T8511G1070)

Thermostat

Fan Switch: Auto-On;

System Switch: Off-Em Heat-Auto or Cool/Heat

 

 

 

Indicating Lamps: Check Display Indication: Em Heat-Aux Heat

 

 

 

 

 

 

2 stage cool, 2 stage heat; Digital programmable (7 day); Battery backup

8403-034

Part of

Automatic or manual changeover; 1 set-up/set-back period per 24 hours

 

Programmable ventilation terminal for economizer or energy recovery

 

(1F94-80)

Thermostat

 

Fan Switch: Auto-On;

System Switch: Off-Em Heat-Auto or Cool/Heat

 

 

 

 

 

 

Indicating Lamps: Emer-Pump-Malf-Aux

 

 

 

 

 

 

2 stage cool, 3 stage heat; Digital proframmable (5day/2day); Battery backup

8403-027

Part of

Automatic or manual changeover: 4 set-ups/set-back periods per 24 hours

(1F92-71)

Thermostat

Fan Switch: Auto-On;

System Switch: Off-Em Heat-Auto or Cool/Heat

 

 

 

Indicating Lamps: Emer-Pump-Malf-Aux

 

 

 

 

 

 