Air Conditioning Wall-Mount Model Nomenclature
MODEL | WA 3S 3 | |
|
| |
NUMBER |
|
|
|
|
A 10 B P X X
X X
WA – Right Hand | REVISION |
WL – Left Hand | WA - 3 |
| WL - 2 |
CAPACITY |
| |
VOLTS & PHASE | ||
3S - 3 Ton | ||
A - 230/208/60/1 | ||
4S - 4 Ton | ||
B - 230/208/60/3 | ||
5S - 5 Ton | ||
C - 460/60/3 | ||
|
KW
VENTILATION OPTIONS
(See Chart Below)
FILTER OPTIONS
P - 2 inch Pleated
MERV 8
COLOR OPTIONS
X - Beige (Standard)
1 - White
4 - Buckeye Gray
5 - Desert Brown
8 - Dark Bronze
A - Aluminum
S - Stainless Steel
CONTROL MODULES
(See Chart Below)
COIL OPTIONS
X - Standard
1 - Phenolic Coated Evaporator
2 - Phenolic Coated Condenser
3 - Phenolic Coated Evaporator
& Condenser
OUTLET OPTIONS
X - Front (Standard)
Note: For 0KW and circuit breakers (230/208 Volt) or rotary disconnect (460 Volt) applications, insert 0Z in the KW field of the model number.
Ventilation Options
Models |
| All Models | ||
Description | Factory Installed |
| Field Installed | |
Code No. |
| Part No. | ||
|
|
| ||
| B |
| ||
|
|
|
|
|
Motorized Fresh Air Damper |
| M |
| |
|
|
|
| |
Commercial Ventilator - Motorized with Exhaust | V |
| ||
|
|
|
| |
Economizer - School Versions, Enthalpy 4 | S |
| ||
|
|
|
| |
Economizer - Equipment Bldg., Enthalpy 5 | W |
| ||
|
|
|
| |
Economizer - Equipment Bldg., DB Temp 5 | T |
| ||
|
|
|
|
|
Energy Recovery Ventilator - 230 Volt | 3 | R |
| |
|
|
|
|
|
Energy Recovery Ventilator - 460 Volt | 3 | R |
| |
|
|
|
|
|
Door Kit for ERVF (Required) |
| N/A |
| WMDK5- 3 |
|
|
|
|
|
1Intake and exhaust can be independently adjusted.
2Insert color to match unit ("X" = Beige; "4" = Buckeye Gray; etc.)
3WMDK Door Kit must be ordered in addition to ERVF Assembly and ECONWMS & color matched to unit ("X" = Beige; "4" = Buckeye Gray; etc.)
4 Partial Full Flow (75% of Rated Cooling CFM). All ECONWMS versions have 3" deep intake hood.
5 Full Flow (100% of Rated Cooling CFM). ECONWMT2 and 3 have 16" deep intake hood;
Air Conditioning Control Modules |
|
|
| All Models | |||||
|
| AVAILABLE CONTROL OPTIONS |
|
|
|
| |||
HPC1 | LPC 2 | CCM 3 | LAC 4 |
| ALR 5 | SK 6 | DDC 7 | Factory Installed Code | Field Installed Part |
STD | STD | STD |
|
|
| STD |
| X | N/A |
STD | STD | STD | z |
|
| STD |
| H | |
STD | STD | STD | z |
| z | STD |
| J | Factory Only |
STD | STD | STD | z |
| z | STD | z | V 7 | Factory Only |
|
|
|
|
|
|
|
|
|
|
STD = Standard equipment for these specified models.
1 HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
2 LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 3.
3 CCM. Compressor control module has adjustable
4 LAC. Low ambient control permits cooling operation down to 0°F.
5 ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls.
6 SK. Start kit standard on all
7 DDC. Incorporates 4 additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status.
Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com
Due to our continuous product improvement policy, all specifications subject to change without notice.
Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.
Form No.
S3378
November, 2012
Supersedes:
Form No. | |
Supersedes | |
Page | 12 of 12 |