Electric Heat Table

Nominal

 

At 240V (1)

 

 

At 208V (1)

 

 

At 480V (2)

 

 

At 460V (2)

 

KW

Kw

1-Ph Amps

3-Ph Amps

Btuh

Kw

1-Ph Amps

3-Ph Amps

Btuh

Kw

3-Ph Amps

Btuh

Kw

3-Ph Amps

Btuh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.0

5.0

20.8

 

17,065

3.75

18.0

 

12,799

 

 

 

 

 

 

6.0

6.0

 

14.4

20,478

4.50

 

12.5

15,359

6.0

7.2

20,478

5.52

6.9

18,840

8.0

8.0

33.3

 

27,304

6.00

28.8

 

20,478

 

 

 

 

 

 

9.0

9.0

 

21.7

30,717

6.75

 

18.7

23,038

9.0

10.8

30,717

8.28

10.4

28,260

10.0

10.0

41.7

 

34,130

7.50

36.1

 

25,598

 

 

 

 

 

 

15.0

15.0

62.5

36.1

51,195

11.25

54.1

31.2

38,396

15.0

18.0

51,195

13.80

17.3

47,099

20.0

20.0

83.3

 

68,260

15.00

72.1

 

51,195

 

 

 

 

 

 

(1)These electric heaters are available in 230/208V units only.

(2)These electric heaters are available in 480V units only.

Heater Packages - Field Installed WA3, WA4 & WA5S

• Designed for adding Electric Heat to 0 KW Units

 

• ETL – US & Canada Listed

 

 

• Circuit Breaker Standard on 230/208V Models

 

• Rotary Disconnect Standard on 460V Models

 

Air Conditioner

-A00 Models

 

-B00 Models

 

-C00 Models

 

230/208-1

 

230/208-3

 

460-3

 

Models

 

 

 

Heater Model #

KW

Heater Model #

KW

Heater Model #

KW

 

 

EHWA4S-A05

5

 

 

 

 

 

EHWA5S-A08

8

EHWA3S-B06

6

EHWA5S-C06

6

WA3S3

EHWA4S-A10

10

EHWA5S-B09

9

EHWA5S-C09

9

 

EHWA4S-A15

15

EHWA5S-B15

15

EHWA5S-C15

15

 

EHWA4S-A20

20

 

 

 

 

 

EHWA4S-A05

5

 

 

 

 

 

EHWA5S-A08

8

EHWA5S-B06

6

EHWA5S-C06

6

WA4S3

EHWA4S-A10

10

EHWA5S-B09

9

EHWA5S-C09

9

 

EHWA4S-A15

15

EHWA5S-B15

15

EHWA5S-C15

15

 

EHWA4S-A20

20

 

 

 

 

 

EHWA5S-A05

5

 

 

 

 

 

EHWA5S-A08

8

EHWA5S-B06

6

EHWA5S-C06

6

WA5S3

EHWA5S-A10

10

EHWA5S-B09

9

EHWA5S-C09

9

 

EHWA5S-A15

15

EHWA5S-B15

15

EHWA5S-C15

15

 

EHWA5S-A20

20

 

 

 

 

Heater Packages - Field Installed WL3, WL4 & WL5S

• Designed for adding Electric Heat to 0 KW Units

 

• ETL – US & Canada Listed

 

 

• Circuit Breaker Standard on 230/208V Models

 

• Rotary Disconnect Standard on 460V Models

 

Air Conditioner

-A00 Models

 

-B00 Models

 

-C00 Models

 

230/208-1

 

230/208-3

 

460-3

 

Models

 

 

 

Heater Model #

KW

Heater Model #

KW

Heater Model #

KW

 

 

EHWA4S-A05L

5

 

 

 

 

 

EHWA5S-A08L

8

EHWA3S-B06L

6

EHWA5S-C06L

6

WL3S2

EHWA4S-A10L

10

EHWA5S-B09L

9

EHWA5S-C09L

9

 

EHWA4S-A15L

15

EHWA5S-B15L

15

EHWA5S-C15L

15

 

EHWA4S-A20L

20

 

 

 

 

 

EHWA4S-A05L

5

 

 

 

 

 

EHWA5S-A08L

8

EHWA5S-B06L

6

EHWA5S-C06L

6

WL4S2

EHWA4S-A10L

10

EHWA5S-B09L

9

EHWA5S-C09L

9

 

EHWA4S-A15L

15

EHWA5S-B15L

15

EHWA5S-C15L

15

 

EHWA4S-A20L

20

 

 

 

 

 

EHWA5S-A05L

5

 

 

 

 

 

EHWA5S-A08L

8

EHWA5S-B06L

6

EHWA5S-C06L

6

WL5S2

EHWA5S-A10L

10

EHWA5S-B09L

9

EHWA5S-C09L

9

 

EHWA5S-A15L

15

EHWA5S-B15L

15

EHWA5S-C15L

15

 

EHWA5S-A20L

20

 

 

 

 

Form No.

S3378-1112

Supersedes

S3378-712

Page

7 of 12

Page 7
Image 7
Bard WA3S, WL3S, WL5S manual Electric Heat Table, Heater Packages Field Installed WA3, WA4 & WA5S, Ph Amps Btuh

WA3S, WA5S, WL5S, WL3S specifications

Bard WA5S, WL3S, WL5S, and WA3S are advanced heating, ventilation, and air conditioning (HVAC) systems designed to deliver efficient and reliable climate control solutions for various indoor environments. These models are particularly well-suited for residential and commercial applications, prioritizing energy efficiency, comfort, and user-friendly features.

One of the notable features of Bard's HVAC systems is their impeccable design, which allows for easy installation in diverse settings, including utility rooms and sidewalls. The WA series, known for its robust wall-mounted units, offers flexibility in placement while maintaining optimal airflow and temperature control. The WL series enhances this further with a high-efficiency heat pump option, providing both heating and cooling capabilities in a single unit, thereby streamlining operations and reducing energy costs.

Energy efficiency is a hallmark of Bard's technology. These models typically come equipped with high Seasonal Energy Efficiency Ratios (SEER) and Heating Seasonal Performance Factors (HSPF). This means they consume less electric energy while providing superior heating and cooling performance, contributing to lower utility bills and a reduced carbon footprint. The innovative design also reduces noise levels during operation, creating a more pleasant indoor environment.

Another significant aspect of the Bard WA and WL series is their durable construction. Built to withstand various climatic conditions, these HVAC systems use high-quality materials that ensure longevity and reliability. The units feature corrosion-resistant finishes and sturdy components capable of withstanding harsh indoor and outdoor environments.

Incorporated smart technologies provide added convenience. Many of these models support programmable thermostats and zoning systems, allowing users to customize their comfort levels according to individual preferences. This not only promotes comfort but also enhances energy savings, as heating and cooling can be adjusted based on occupancy and usage patterns.

Furthermore, Bard's commitment to easy maintenance is evident in the design of these units. Access panels are strategically placed to simplify service requirements, while filter maintenance is straightforward, ensuring optimal performance and longevity.

Overall, Bard WA5S, WL3S, WL5S, and WA3S systems stand out in the HVAC market for their combination of energy efficiency, flexibility, durability, and user-friendly features, making them a compelling choice for those looking to enhance their indoor climate control solutions.