1.0 Quick Reference Guide

The Easy menu button

Programmable Operator Unit (POU)

24 hour time bar for central heating and domestic hot water - shows active programme times

- Default 6am - 9am, 11am - 12pm & 15pm - 22pm

04. November

2008

08:50

Tuesday

 

 

Commonly required functions are available more quickly via the easy menu button. To access, press the easy menu button and scroll through confirm your selection by pressing the dial button.

Commonly required functions are shown in order below: -

1.Standby/operation - the on/off switch - in the off mode frost protection for the appliance is active: displays when in standby.

2.Hot water boost - The domestic hot water is heated to the required temperature once.

3.Central heating mode CH1 - easy access to change the operating mode see Section 7.1

Easy Menu

Button

Standby

Menu Button

4.Room temperature CH1 - The central heating setpoint temperature can be altered permanently.

5.Hot water mode - easy access to change the operating mode see Section 7.4

6.Hot water temp setpoint - The hot water setpoint temperature can be altered permanently as long as a tank sensor is fitted. If no sensor is fitted --- appears.

Dial Knob (Turn /Push Select)

Display Descriptions

Burner in Operation 1 - Engine 2 - Supplementary

Heating to the Room temperature Set Point

Heating to the Reduced Set Point

Central Heating Times Active

DHW Time Active

Combustion Check Function Active

Holiday Function Active

Text 1

Text 2

Text 3

Manual Overide

Time Switch Function Active

Communication between POU & PCB Control Established

POU Programmed as Room Unit

Error Message

Standby - Appliance ON/OFF

Outdoor Sensor Connected

System / Appliance Attention Required

Maintenance / Special Mode

Change Battery (only if radio control fitted)

Display showing all available segments

© Baxi Heating UK Ltd 2010

3

Page 3
Image 3