12.0CHANGING COMPONENTS
12.21Diverter Valve Assembly (Cont)
CH Pressure Differential Valve (Fig. 71)
1. | Remove the DHW pressure differential valve as |
described above. | |
2. | From the brass diverter manifold undo the nut on |
the heating flow pipe. Remove the screw securing the | |
diverter manifold to the appliance lower bracket. | |
3. | Disconnect the pressure gauge capillary from the |
diverter manifold and remove the two wires from the | |
microswitch. | |
4. | Prise off the spring clip securing the |
to the diverter manifold and disconnect the sensing | |
pipe. |
Microswitch &
Bracket
Diaphragm
Heating
Flow Pipe
Fig. 71
Central Heating
Pressure Differential
Valve
Sensing Pipe
Pipe
Spring Clip
5. | Ease the diverter manifold out of the plate heat |
exchanger manifold. Remove the assembly from the | |
appliance. | |
6. | Undo the screw securing the microswitch bracket |
to the valve body. The sensor may now be | |
dismantled to examine the diaphragm. | |
7. | To examine the diaphragm hold the assembly |
securely and carefully remove the four screws. The | |
diaphragm spring will force the two halves of the | |
valve apart. | |
8. | Carefully examine the diaphragm and replace it if |
there is any damage. | |
9. | Reassemble in reverse order. |
CH Pressure Microswitch (Fig. 71)
1.Remove the two wires from the pressure microswitch.
2.Undo the screw securing the microswitch bracket to the valve body.
3.Reassemble in reverse order.
Diverter Manifold
Pressure Gauge
Capillary
12.22Flow Regulator (Figs. 71 & 72)
1.Undo the filter cartridge from the inlet/return manifold.
Cartridge
2. Unscrew the venturi and remove the flow regulator.
3. Check the cleanliness of the filter gauze, rinsing thoroughly in clean water as necessary. Fit the new flow regulator and reassemble in reverse order.
Body
Filter Gauze
Fig. 85
Flow
Regulator
Venturi
Inlet / Return Manifold
Fig. 72
Publication No. 5111811 | 37 |