12.21Diverter Valve Assembly (Cont)

12.0CHANGING COMPONENTS

12.21Diverter Valve Assembly (Cont)

CH Pressure Differential Valve (Fig. 71)

1.

Remove the DHW pressure differential valve as

described above.

2.

From the brass diverter manifold undo the nut on

the heating flow pipe. Remove the screw securing the

diverter manifold to the appliance lower bracket.

3.

Disconnect the pressure gauge capillary from the

diverter manifold and remove the two wires from the

microswitch.

4.

Prise off the spring clip securing the by-pass pipe

to the diverter manifold and disconnect the sensing

pipe.

Microswitch &

Bracket

Diaphragm

Heating

Flow Pipe

Fig. 71

Central Heating

Pressure Differential

Valve

Sensing Pipe

By-pass

CH Pressure Differential Valve (Fig. 71) Pipe

CH Pressure Microswitch (Fig. 71)12.22Flow Regulator (Figs. 71 & 72)Manual backgroundManual backgroundManual background Spring Clip

5.

Ease the diverter manifold out of the plate heat

exchanger manifold. Remove the assembly from the

appliance.

6.

Undo the screw securing the microswitch bracket

to the valve body. The sensor may now be

dismantled to examine the diaphragm.

7.

To examine the diaphragm hold the assembly

securely and carefully remove the four screws. The

diaphragm spring will force the two halves of the

valve apart.

8.

Carefully examine the diaphragm and replace it if

there is any damage.

9.

Reassemble in reverse order.

CH Pressure Microswitch (Fig. 71)

1.Remove the two wires from the pressure microswitch.

2.Undo the screw securing the microswitch bracket to the valve body.

3.Reassemble in reverse order.

Diverter Manifold

Pressure Gauge

Capillary

12.22Flow Regulator (Figs. 71 & 72)

1.Undo the filter cartridge from the inlet/return manifold.

Cartridge

2. Unscrew the venturi and remove the flow regulator.

3. Check the cleanliness of the filter gauze, rinsing thoroughly in clean water as necessary. Fit the new flow regulator and reassemble in reverse order.

Manual background Body

Filter Gauze

Fig. 85

Flow Manual background

Regulator

Venturi