15.0 FAULT FINDING
I |
|
| |
Ensure that mains input | |||
| |||
| terminal L is Live (230V) and N | ||
| is Neutral (0V) | ||
|
| ||
| YES |
| |
|
|
|
Check and correct if necessary
1.Flame sensing electrode and lead connections
2.Electrode position
Flame current should be 1 µA approx.
YES
NO
Replace PCB
Replace flame sensing electrode
J
Boiler overheat thermostat | NO | |||||
operated or faulty, i.e. continuity | ||||||
|
| |||||
|
| |||||
across thermostat terminals |
|
| ||||
|
|
|
|
| ||
YES |
|
|
|
|
| |
|
|
|
|
|
| |
|
|
| Replace |
|
| |
|
|
| PCB |
|
| |
|
|
|
|
|
|
Allow to cool. Continuity
across thermostat terminals
more than 1.5 ohm
YES
Replace boiler
overheat thermostat
K
L
Check terminal 1 of ON/OFF/RESET selector is in connection with PCB - M1 connector terminal 16 Check electrical continuity across terminals 1 & a of ON/OFF/RESET selector when turned to ‘Reset’ position
Press the reset button on the flue overheat thermostat. If the boiler does not relight or repeatedly cuts out check the operation of the flue system or replace the flue overheat thermostat. If the flue overheat thermostat has not been activated see section ‘D’
NO
YES
Replace ON/OFF/RESET selector
Replace PCB