P73335u_UPS_man.qxd 4/30/01 12:19 PM Page 17

Replacing Battery (continued)

The Regulator PRONetUPS Series provides a convenient and easy way to replace batteries. If batteries are in poor condition, follow the proper procedure for battery replacement.

6-1 Notice

When replacing batteries, always use the same type as the previous one.

Do not dispose the battery or batteries in a fire as they may explode.

Do not open or mutilate the battery or batteries as released electrolyte is toxic and harmful to skin and eyes.

A battery may present a risk of electric shock and high short circuit current. The following precaution should be observed when replacing batteries:

Remove watches, rings, or other metal objects.

Use tools with insulated handles.

6-2 Battery Replacement Procedures

1.Hold the top of the front panel, tilt it out and pull it carefully away from the chassis.

Step 1

Grasp and tilt out and down

En

2.Loosen the bottom of the front panel from the chassis and place it on the top of the UPS. Be cautious so as not to pull the ribbon cable and touch the LED printed circuit board.

3.Use a Phillips screwdriver to remove and open the battery door.

4.Carefully and smoothly pull the battery out of the UPS.

Step 2

Place the front panel above

Step 4

Pull battery out

Step 3

Use a Phillips screwdriver to release the battery door

17

Page 21
Image 21
Belkin F6C1000-EUR, F6C700-EUR, F6C1400-EUR user manual Battery Replacement Procedures