Cleaning3
Clean the EZ Melt after every use. Follow these steps:
1.Turn on the heat and the pump.
2.Press the foot pedal to pump shortening out of the EZ Melt and into a metal container or fryer kettle.
3.When you cannot pump any more shortening out of the EZ Melt, release the foot pedal. Turn off the heat and the pump.
4.Disconnect the EZ Melt from the power source.
5.Allow the shortening in the EZ Melt kettle to cool to 115 F/46 C.
WARNING
Thoroughly clean and dry the floor if shortening, water, or other materials are spilled. Materials spilled on the floor may cause serious injury and loss of life.
7.Remove the cube melter.
8.Loosen the two fasteners at the back of the heater head, lift it off the kettle and place it in a clean safe place. The foot valve and cord will unsnap from the frame. See Figure
WARNING
Hot shortening can cause serious injury.
6.Clean the EZ Melt filter. Follow these steps:
a.Allow the filter assembly to cool to the touch.
b.Lift off the filter assembly, holding it by the frame.
c.Invert the filter assembly over a sink or garbage can and shake the sediment off of it.
d.Unsnap the filter to remove it from the filter frame.
e.Rinse the remaining shortening and
crumbs off of the filter. | Figure |
| (Place heater head as shown above so no |
| damage is done to the element.) |
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone
10 | EZ Melt Model EZ18, EZ24, EZ34 |