7.Position the EZ Melt so the filter is directly under the drain in the fryer kettle.
8.Reach under the table and slowly open the fryer’s drain valve.
9.Move the HEAT and PUMP switches of the EZ Melt to the ON position.
10.Hold the insulated handle of the hose. Direct the nozzle into the fryer kettle. Press the foot pedal and rinse the kettle with shortening. Do not let shortening splash out of the kettle!
WARNING
To avoid burning yourself, never hold or touch the metal portion of the nozzle while the machine is in use. Wear protective gloves.
WARNING
Thoroughly clean and dry the floor if shortening, water, or other materials are spilled. Materials spilled on the floor may cause serious injury and loss of life.
11.After you have rinsed all the loose particles out of the fryer kettle, release the foot pedal.
12.After the shortening has drained out of the fryer kettle and through the EZ Melt filter, close the drain valve.
13.Turn the EZ Melt off. Make sure that both the HEAT and PUMP switches are in the OFF position.
14.Disconnect the rinsing hose assembly. Hold the two ends of the hose up so shortening does not drip out. Hang the hose vertically over a pan so shortening will drip into the pan.
15.Bring the supply hose back to the EZ Melt, holding the two ends of the hose up so shortening does not drip out.
16.Securely attach the supply hose to the hose connector. Make sure the outlet nozzle is securely mounted to the fryer, with the opening inside the kettle.
17.Move the HEAT and PUMP switches to the ON position. Press the foot pedal to supply filtered shortening to the fryer.
18.Before you filter shortening again, empty the EZ Melt filter. Follow these steps:
a.Allow the filter assembly to cool to the touch.
b.Lift off the filter assembly, holding it by the frame.
c.Invert the filter assembly over a sink or garbage can and shake the sediment off of it. DO NOT rinse the filter.
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone
8 | EZ Melt Model EZ18, EZ24, EZ34 |