Indicators

Indicators

Light

Status & Description

Power events

Orange

Off

Off

Stand-by mode.

Green

Off

Off

Powering up.

Flashing

 

 

 

Green

Off

Off

Normal operation.

Orange

Off

Off

Normal power-down cooling

Flashing

 

 

 

 

 

Lamp events

 

 

 

 

Off

Off

Red

Lamp error in normal operation

Orange

Off

Red

Lamp is not lit up

Flashing

 

 

 

 

 

Thermal events

Off

Red

Off

Fan 1 error (the actual fan speed is +25% outside

the desired speed)

 

 

 

Off

Red

Red

Fan 2 error (the actual fan speed is +25% outside

the desired speed)

 

 

 

Off

Red

Green

Fan 3 error (the actual fan speed is +25% outside

the desired speed)

 

 

 

Off

Red

Orange

Fan 4 error (the actual fan speed is +25% outside

the desired speed)

 

 

 

Orange

Red

Red

Temperature 1 error (over limited temperature)

Red

Red

Red

Thermal Sensor 1 open error

Green

Red

Red

Thermal Sensor 1 short error

Off

Green

Red

Fan IC #1 I2C Connection error

Orange

Red

Green

Temperature 2 error (over limited temperature)

Red

Red

Green

Thermal Sensor 2 open error

Green

Red

Green

Thermal Sensor 2 short error

Off

Green

Orange

Fan IC #2 I2C Connection error

Off

Red

Off

Fans do not rotate in the process of powering up