7. BUILD THE FRAMEWORK
!WARNING
When building framework, always follow all applicable construction codes and standards.
The framework must be sized to support the total weight of the hood. Refer to the table below for total weight of the hood, according to the type of blower chosen.
HOOD WIDTH | WITH P6 INTERIOR BLOWER | WITH P12 INTERIOR BLOWER | WITH |
42” | 71 LB | 84 LB | 52 LB |
54” | 86 LB | 99 LB | 67 LB |
7.1SUGGESTED FRAMEWORK FOR INSTALLATION WITH DECORATIVE FLUE COVER AEIWP SERIES
In the ceiling material,
| 28¾” |
|
|
|
| 28½” |
|
|
|
| SUPPORTING STUDS |
| Studs flush | |
12½” |
| with ceiling material | ||
| 125/8” | |||
max. |
| ceiling | ceiling | |
|
| |||
|
|
| material | material |
C |
| C |
|
|
L | 27” | L |
|
|
HD0227A |
|
|
| |
|
|
|
|
Using provided wood screws no. 10 x 1.5” and washers, assemble both mounting brackets (included with the optional decorative flue cover) to the framework. See illustration beside.
HD0228A |
7.2SUGGESTED FRAMEWORK FOR INSTALLATION WITH DRYWALL TRIM ATDIP SERIES
Below is the suggested framework for both 42” and 54” width hoods to be installed with drywall trim ATDIP Series. Refer to the table and illustrations below for the dimensions according to the hood width. Using provided wood screws no. 10 x 1.5” and washers, assemble both mounting brackets (included with the optional drywall trim) to the framework.
HOOD WIDTH | A WITH 5/8” DRYWALL | A WITH 1/2” DRYWALL | B WITH 5/8” DRYWALL | B WITH 1/2” DRYWALL | C |
42” | 115⁄8” | 117⁄8” | 285⁄8” | 287⁄8” | 10” MINIMUM |
54” | 115⁄8” | 117⁄8” | 405⁄8” | 407⁄8” | 10” MINIMUM |
FRAMEWORK 42’’ HOOD |
HD0235 |
FRAMEWORK 54’’ HOOD | |
C | C |
L | L |
| 27¼” |
FRAMEWORK | C |
TOP VIEW | |
HD0237 |
|
- 8 -