Billion Electric Company Billion BiPAC 7402NXL 802.11n 3G/ADSL2+ VPN Firewall Router

Models: 7402NX

1 128
Download 128 pages 9.1 Kb
Page 83
Image 83
PING for Keep Alive:

Billion BiPAC 7402NX(L) 802.11n 3G/ADSL2+ (VPN) Firewall Router

negotiates and establishes SA on behalf of IPSec, an IKE SA is used by IKE.

Phase 1 (IKE): To issue an initial connection request for a new VPN tunnel. The range can be from 5 to 15,000 minutes, and the default is 480 minutes.

Phase 2 (IPSec): To negotiate and establish secure authentication. The range can be from 5 to 15,000 minutes, and the default is 60 minutes.

A short SA time increases security by forcing the two parties to update the keys. However, every

time the VPN tunnel re-negotiates, access through the tunnel will be temporarily disconnected.

PING for Keep Alive:

None: The default setting is None. To this mode, it will not detect the remote IPSec peer has been lost or not. It only follows the policy of Disconnection time after no traffic, which the remote IPSec will be disconnected after the time you set in this function.

PING: This mode will detect the remote IPSec peer has lost or not by pinging specify IP address.

DPD: Dead peer detection (DPD) is a keeping alive mechanism that enables the router to be detected lively when the connection between the router and a remote IPSec peer has lost. Please be noted, it must be enabled on the both sites.

PING to the IP: It is able to IP Ping the remote PC with the specified IP address and alert when the connection fails. Once alter message is received, Router will drop this tunnel connection. Re-establish of this connection is required. Default setting is 0.0.0.0 which disables the function.

Interval: This sets the time interval between Pings to the IP function to monitor the connection status. Default interval setting is 10 seconds. Time interval can be set from 0 to 3600 second, 0 second disables the function.

Ping to the IP

Interval (sec)

Ping to the IP Action

 

 

 

0.0.0.0

0

No

 

 

 

0.0.0.0

2000

No

 

 

 

xxx.xxx.xxx.xxx (A valid IP Address)

0

No

 

 

 

xxx.xxx.xxx.xxx(A valid IP Address)

2000

Yes, activate it in every 2000

 

 

second.

 

 

 

Disconnection Time after no traffic: It is the NO Response time clock. When no traffic stage time is beyond the Disconnection time set, Router will automatically halt the tunnel connection and re-establish it base on the Reconnection Time set. 180 seconds is minimum time interval for this function.

Reconnection Time: It is the reconnecting time interval after NO TRAFFIC is initiated. 3 minutes is minimum time interval for this function.

Click Edit/Delete to save your changes.