HUMIDIFIER SAFETY
PLEASE READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT SAFEGUARDS
When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
1.Read all instructions before using the appliance.
2.To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.
3.Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs or near heat registers.
4.DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. DO locate your humidifier on an inside wall near an electrical outlet. The humidifier should be at least 4” away from the wall for best results.
5.NEVER place humidifier in an area where it is accessible to children. NEVER use humidifier in a closed room, particularly where a child may be sleeping, resting, or playing (a closed room may result in excessive humidity).
6.WARNING: Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet. Failure to heed this warning may cause personal injury. Be sure to unplug the unit by pulling on the plug and not the cord.
7.Never place anything over moisture outlet when the unit is running.
8.NEVER drop or insert any object into any openings. DO NOT place hands, face or body directly over or near Moisture Outlet while unit is in operation. DO NOT cover Moisture Outlet while the unit is operating.
9.DO NOT operate any appliance with a damaged cord or plug, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Return appliance to manufacturer for examination, electrical or mechanical adjustment, or repair.
10.Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. The use of attachments not recommended or sold the manufacturer may cause hazards.
11.DO NOT use outdoors.
12.Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the humidifier. NEVER place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.
13.DO NOT allow the Moisture Outlet to directly face the wall. Moisture could cause damage, particularly to wall paper.
14.Humidifier should be unplugged when not in use.
15.NEVER tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit. If you have a warm mist humidifier, DO NOT attempt to remove the water tank within 15 minutes after the humidifier is turned off and unplugged. Serious injury may result.
16.This humidifier requires daily and weekly maintenance to operate appropriately. Refer to daily and weekly cleaning procedures. Use only cleaners and additives recommended by the manufacturer. Never use gasoline, glass cleaner,furniture polish, paint thinner, or other household solvents to clean any part of the humidifier.
17.Excessive humidity in a room can cause water condensation on windows and some furniture. If this happens, turn the humidifier OFF.
18.Do not use humidifier in an area where humidity level is in excess of 50%. Use a hygrometer, available at your local retailer or through the manufacturer to measure the humidity.
19.DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.
20.Never place housing under water flow, or immerse in liquids.
21.DO NOT plug in the cord with wet hands, electric shock could result.
22.DO NOT pour water in any openings other than the water tank.
23.If you have a warm mist humidifier, allow unit to cool before refilling water tank or maintenance as the heater bulb is hot.
24.To prevent damage to surfaces, do not place humidifier under overhanging surfaces.
25.NEVER operate unit without water in the tank.
26.Do not move unit after it has been used until unit cools completely.
27.Use both hands when carrying full tank of water.
PLEASE SAVE THESE
INSTRUCTIONS
CONSUMER SAFETY INFORMATION
NOTE: This is an electrical appliance and requires attention when in use.
NOTE: If moisture forms on the walls or windows of the room, turn off the humidifier. The room already has plenty of humidity and additional moisture may cause damage.
NOTE: DO NOT block air inlet or outlet.
THIS PRODUCT IS EQUIPPED
WITH A POLARIZED PLUG (a plug having one blade wider than the other). This plug will fit into the power outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does
not fit, contact qualified personnel to install the proper outlet.
DO NOT DEFEAT THE SAFETY PURPOSE OF THIS POLARIZED PLUG IN ANY WAY.
The length of cord used on this appliance was selected to reduce the hazards of becoming tangled in, or tripping over a longer cord. If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the rating of the humidifier. Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.
HOW COOL MIST WORKS
Your Bionaire® Cool Mist humidifier draws dry air through the rear air intake grill area. This air is then passed through 2 moisture–laden wick filters which retains the minerals and deposits. The resulting moist air is directed back into the room from the top air grill.
NOTE: This humidification system provides a cool, invisible moisture output. It is normal not to see the mist.
NOTE: A humidity level below 20% can be unhealthy and uncomfortable. The recommended humidity level is between 40%-50%.
BEFORE USE (PRE-OPERATING INSTRUCTIONS)
1.Be sure the humidifier is switched to OFF and the unit is disconnected from the electrical outlet.
2.Take housing off base and remove foam packing beneath the housing. Place housing back on base.
3.Select a location for your humidifier, on a flat surface, about 4” away from the wall. DO NOT place the humidifier on a finished floor or near furniture, which
can be damaged by moisture or water. Place on a moisture-resistant surface.
FILLING THE WATER TANK
1.Remove the tank from the base of the humidifier and bring to the faucet. Turn the tank upside down and twist off the tank cap by turning counter clockwise. Fill tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank FIRMLY.
2.When full, carry tank to the humidifier and place onto the base. The tank holds 3/4 gallon of water and the base holds 1/4 gallon of water. The tank will immediately begin to empty into base.
3.Plug the power cord into a 120V AC electrical outlet.
Figure 1 | Filter Monitor |
Control Panel |
Reservoir Handle | |
| Housing |
Water Reservoir
Wick Holder
OPERATING INSTRUCTIONS
Your humidifier is equipped with a technologically advanced Digital Electronic Humidistat. You can set the humidifier to run continuously in manual mode or set the Digital Electronic Humidistat to your desired humidity setting. The Digital Electronic Humidistat will automatically turn the humidifier ON or OFF, depending on the preset comfort level. The comfort level ranges between 35% and 55% relative humidity.
MANUAL MODE INSTRUCTIONS
1.Plug the humidifier into a 120V AC electrical outlet.
2.To start the unit, push the mode button once for the HIGH (II) manual setting. (See Figure 2)
3.Press the button again for the LOW (I) manual setting. (See Figure 2)
4.To stop the unit, press and hold the button for two seconds, or keep pressing the button until all the humidity indicators are OFF.
NOTE: In Manual Mode, only the LOW (I) or HIGH (II) power light will be lit.
DIGITAL HUMIDISTAT INSTRUCTIONS
To take advantage of the Digital Electronic Humidistat,
press the mode button until the speed is set in either the HIGH (II) or LOW (I) setting, and the desired Humidity is set. When the humidity level rises above the set humidity, the humidifier will stop. When the humidity level drops below the set humidity, the humidifier will turn on automatically.
NOTE: When the Digital Electronic Humidistat is set, either the HIGH (II) or LOW (I) power light and the percent humidity light will remain lit during operation. (See Figure 2)
Figure 2
B. RIGHT LEDS
D
C. mode BUTTON
D. RC SENSOR LENS
NOTE: Allow up to 30 minutes for the filter to fully absorb water and for the unit to produce moisture.
NOTE: The Digital Humidifier has memory. This means that when you turn the unit back on, it will be at the last setting the humidifier was set at.
If you do not plan to use the humidifier for two or more days, make sure any residual water is drained from the water tank, base and wick filter to prevent algae or bacteria growth.
| REMOTE INSTRUCTIONS | |
| 1. | Insert 2 AAA batteries into | |
| Figure 3 |
| | back of remote control. |
| | |
| 2. | Press the button on remote | |
| | to begin operation. | |
3.Use the remote to control the same features as the base unit.
NOTE: Do not mix new and old batteries. Do not mix alkaline,
standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.
when you clean the filter. The | Figure 4 | | | | |
water tray is a convenient way to | | | h | | GoGoo |
carry the filter to prevent dripping. | | | s r | | do |
| ha e | | d |
s | rlt | | | |
a W | ei | | | |
W | iltF | | | |
2. Mix 1 gallon warm tap water with | F | | | | | |
Off/Fill | | | |
1 teaspoon concentrated | F | | | T M |
antibacterial liquid dish washing | | | n |
| i | | |
| | lt | |
| | ea |
soap. | | | | erCl | |
| | | | | |
3. Fully submerge filter in soap solution for 15-20 minutes.
4. Dunk filter in soap solution several times then gently press to release the soapy water. Be sure not to wring, pull or scrub filter as this will degrade the filter.
5. Run under cool tap water until there is no soap remaining. Some discoloration may still be visible, this is normal and does not affect performance.
6. Gently shake or press the filter to remove excess water.
7. The filter can be put directly into the humidifier while still damp if it is to be used right away, or allow filter to dry completely if humidifier is to be stored.
| to turn the unit OFF and disconnect from the electrical |
| outlet. |
2. | Remove the housing and the tank from the humidifier |
| and place in sink or tub. |
3. | Carry the base of the unit to the sink, remove the wick |
| holder and wicks, place in sink, drain any remaining |
| water and rinse thoroughly to remove any sediment or |
| dirt. Wipe clean, and dry with a clean cloth or paper |
| towel. NOTE: the base and wick holder are dishwasher |
| safe TOP RACK ONLY. |
4. | Drain the water from the tank into the sink and rinse |
| tank thoroughly. Wipe clean, and dry with a clean cloth |
| or paper towel. |
5. | Put filters back in wick holder, replace on base, replace |
| the housing, then refill tank with cool tap water as |
| instructed earlier in the Filling Instructions. Do not |
| overfill. |
6. | Follow Operating Instructions. |
WEEKLY MAINTENANCE
time:
1.Do not leave filters in unit.
2.Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season.
3.Place the humidifier in the original carton and store in a cool, dry place.
4.Follow cleaning instructions before and after storing filters.
SERVICE INSTRUCTIONS
1. | Do NOT attempt to repair or adjust any electrical or |
| mechanical functions on this unit. Doing so will void the |
| warranty. The inside of the unit contains no user |
| serviceable parts. All servicing should be performed by |
| qualified personnel only. |
2. | If you need to exchange the unit, please return it in its |
Question
•What are the variables that affect run time?
•How do I remove film on water tank?
•How can I extend the run time?
Answer
The estimated run time for this humidifier is based on average room conditions. The actual run time of your humidifier is dependent on numerous variables such as:
✔Air exchange in the room where the humidifier is placed.
✔Room construction of the room where the humidifier is placed.
✔Temperature of the room where the humidifier is placed.
✔Humidity levels in the room where the humidifier is placed.
✔Movement of occupants and the opening and closing of doors in the room where the humidifier is placed.
✔Home furnishings in the room where the humidifier is placed.
✔See Daily Maintenance instructions. Regular cleaning is recommended.
✔Run your unit on the lowest setting.
✔If your unit has electronics, set it to your desired humidity level. The unit will turn on and off, which will extend the run time.
✔Fill the tank all the way full, place it on the base, let the water empty into the base until it stops bubbling, then refill the tank full again. This ensures maximum water capacity and will extend run time.
A. This Warranty applies only to the original purchaser of |
this product. |
B. This Warranty applies ONLY to repair or replacement of |
any supplied or manufactured parts of this product that, |
upon inspection by JCS/THG, LLC authorized personnel, |
is shown to have failed in normal use due to defects in |
material or workmanship. JCS/THG, LLC will determine |
whether to repair or replace the unit. This Warranty |
does not apply to installation expenses. |
C. Operating this unit under conditions other than those |
recommended or at voltages other than the voltage |
indicated on the unit, or attempting to service or modify |
the unit, will render this WARRANTY VOID. |
D. Unless otherwise proscribed by law, JCS/THG, |
LLC shall not be liable for any personal injury, |
property or any incidental or consequential |
damage of any kind resulting from malfunctions, |
| handling, and |
| d) The model number of the unit and the problem |
| you are having. (Enclose in an envelope and tape |
| directly to the unit before the box is sealed.) |
3. | JCS/THG, LLC recommends you ship the package |
| U.P.S. ground service for tracking purposes. |
4. | All shipping charges must be prepaid by you. |
5. | Mark the outside of your package: |
Bionaire
JCS/THG, LLC
303 Nelson Avenue
Neosho, MO 64850
SHIPPING AND HANDLING CHARGES: $10.00 (USD)
This Warranty gives you specific legal rights, and you may have other rights which vary from state to state. The provisions of this Warranty are in addition to, and not a
replacement part. The part number for this filter is: BWF100P.
CLEANING AND MAINTENANCE INSTRUCTIONS
Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use.
In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the water tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up.
1.Repeat steps 1-4 above.
2.Clean the base by partially filling the base with one 8-oz cups of undiluted white vinegar, or by using Clean-AwayTMSolution (DMS216) by the manufacturer. Leave this solution in the base for 20 minutes, while cleaning the all interior surfaces with a soft brush. Remove base scale by wiping the base with a cloth dampened with undiluted white vinegar.
3.Rinse with clean warm water to remove the cleaning solution before disinfecting the tank.
To Disinfect Humidifier Base and Tank:
1.Fill humidifier base with 1/4 gallon of water and 1/2 teaspoon of chlorine bleach.
2.Fill the tank 1/2 full with water and 1/2 teaspoon of chlorine bleach.
3.Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces.
4.Carefully empty the base and tank after 20 minutes, and rinse with water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel.
5.Check the FilterCleanTM to see if it is time to wash the filters.
6.Refill the water tank as directed with cool tap water, replace the humidifier housing, and turn the unit on.
| 30 days after the date of purchase, please see the |
| enclosed warranty. |
3. | Should your humidifier require service, please call |
| 1-800-253-2764in North America for further assistance. |
4. | If you have any other questions or comments, feel free |
| to write to us or visit our website www.bionaire.com |
Bionaire
JCS/THG, LLC
303 Nelson Avenue
Neosho, MO 64850
Problem
•Unit does not turn on.
•Mist output minimal to none.
•Water leaks from tank.
•Filter turns brown.
•Film on water tank.
•Water in tanks appears cloudy.
•Unit cycles on/off.
•Very tight tank cap.
Solution
✔Drain water from base and allow unit to dry for 15 minutes.
✔Check circuit breaker.
✔Wait 15 minutes before starting humidifier.
✔See Weekly Maintenance under Cleaning and Maintenance Instructions. Regular cleaning is recommended to keep the unit functioning properly.
✔Raise the level of humidity by adjusting the humidistat (see Operating Instructions).
✔Follow filter cleaning instructions in manual.
✔Remove tank cap then replace or reposition ring.
✔Tighten the cap.
✔Follow filter cleaning instructions in manual.
✔In areas with hard water the filter will need to be changed more frequently.
✔See Daily Maintenance under Cleaning and Maintenance instructions. Regular cleaning is recommended to keep the unit functioning properly. To order Clean-AwayTMSolution (DMS216),
call 1-800-253-2764, or visit www.bionaire.com.
✔Follow filter cleaning instructions in manual.
✔Use cool water to fill the water tank and only use Bionaire® care products recommended in this manual.
✔Set the Digital Electronic Humidistat to a higher or lower desired setting.
✔Add liquid soap to cap gasket to ease opening.
E. All parts of this product excluding filters, which are |
covered under separate warranty, are guaranteed for a |
period of 2 years as follows: |
1. Within the first 30 days from date of purchase, the |
store from which you purchased your product |
should replace this product if it is defective in |
material or workmanship (provided the store has |
in-stock replacement.) If you intend to assert any |
claim in connection with the product, please follow |
the instructions in paragraph F. |
2. Within the first 24 months from date of purchase, |
JCS/THG, LLC will repair or replace the product if it |
is defective in material or workmanship, subject to |
the conditions in paragraph G. |
F. If you have any other problem or claim in connection |
with this product, please write to our Consumer Service |
Department. |
G. IMPORTANT RETURN INSTRUCTIONS. Your Warranty |
depends on your following these instructions if you are |
returning the unit to JCS/THG, LLC: |
1. Carefully pack the item in its original carton or other |
suitable box to avoid damage in shipping. |
2. Before packing your unit for return, be sure to |
enclose: |
a) Your name, full address with zip code and |
telephone number |
warranties and other rights and remedies contained in any applicable legislation. To the extent that any provision of this Warranty is inconsistent with any applicable law, such provision shall be deemed voided or amended, as necessary, to comply with such law.
© 2006 JCS/THG, LLC
Bionaire®, the Bionaire logoTM, PERMAtechTM, FilterCleanTM and Clean-AwayTMare trademarks of JCS/THG, LLC.
BCM7255CN06EFM3 | Printed in China |