the Power Knob to I. In about 2-3 minutes, the humidifier will begin to produce moisture.
6.If the refill light remains lit, unplug the humidifier and wait a further 5 minutes.
IMPORTANT:
If you do not plan to use the humidifier for two or more days, make sure any residual water is drained from the water tank and base to prevent algae or bacteria growth.
Replacing the Water Purification Filter
The water purification filter is used to retain minerals in your water and provide a clean moisture output. The filter life is determined by the average daily use of your humidifier and the water hardness in your area. Areas with hard water will require more frequent replacement of the filter. It is strongly recommended that the filter be replaced at least every 2-3 months (depending on use) or when the heating element is starting to gather minerals on it.
To Replace the Filter:
1.Switch the humidifier to 0 - off and unplug. Remove the tank, drain any water from the base, lift out the used filter, and throw it away.
2.Remove the protective bag from the new filter and pre-soak the filter under a cold running tap for 1 minute. Place the soaked filter into the base (see Figure 2) and replace the tank allowing at least 5 minutes for the water to pass before switching the unit ON (I).
Cleaning and Maintenance Instruction
The following maintenance procedures must be routinely followed in order to ensure proper, efficient operation of your humidifier. The unit WILL FAIL if it is not cleaned properly.
Regular cleaning prevents scale build-up on the heating element and tray. It also prevents micro- organisms from growing on the tray and tank. This ensures that maximum efficiency will be achieved.
We cannot over-emphasize how essential proper cleaning is to the maintenance and continued use of your unit and the avoidance of algae or bacteria build-up.
Regular Maintenance
The frequency of maintenance will depend on the average daily use of your humidifier and the water hardness of your area. It is recommended that this procedure is carried out weekly or more regularly if necessary.
1. Before cleaning, set the control to 0 - off
position and unplug the unit from the electrical outlet.
2.Remove the water tank then unlock the misting chamber by rotating the safety lock. Lift mist chamber from the unit's base. Now lift the tray from the base.
3.Empty water and minerals from the tray and wash it through to remove any sediment and dirt that has accumulated in the tray.
NOTE: It is imperative that the tray is cleaned properly. The tray is dishwasher safe for easy cleaning (Top rack of the dishwasher only).
4.Rinse out the tank out and refill with clean cool water.
5.Wipe the heating element clean with a soft cloth after it has had a chance to cool.
WARNING: If the misting chamber is left assembled to the humidifier, it may take up to an hour before the heating element is sufficiently cool to be touched.
This humidifier heats the water producing a clean moisture. Some of the impurities from the water are collected in the Heating Chamber. The Electronic Thermal Control Heating element is lined with a Teflon coating that is designed to provide the easiest cleaning to prolong the operating efficiency of the humidifier.
DO NOT use any metal or hard objects to clean the Heating Element. The coating can be scratched if cleaned improperly.
Never use detergents, gasoline, kerosene, glass cleaner, furniture polish, paint thinner or other household solvents to clean any part of the humidifier.
De-scaling Maintenance
•Scale needs to be removed as it becomes noticeable. We recommend using BionaireTM Clean Away - Humidifier cleaning solution.
•Apply Solution with a plastic brush to scale surfaces. Let it soak until residue is softened. For cleaning the tank, mix 2 capsules of solution with 2 litres of water. Let mixture stand for several minutes, swishing every few minutes. Drain solution and THOROUGHLY RINSE the tank.
If not available follow these instructions:
1.Repeat steps 1-3 in the Maintenance section.
2.Clean the tray by partially filling the tray with 200ml of undiluted white vinegar. If the element is heavily scaled, plug the humidifier into an electrical socket and turn it ON for no longer than 15 seconds. After this time turn the
4
humidifier OFF and unplug it from the electrical outlet.
Let solution stand 20 minutes, cleaning all interior surfaces with a soft brush. Dampen a cloth with undiluted white vinegar and wipe out entire tray to remove scale.
3.Rinse with clean warm water to remove scale and the white vinegar solution before beginning to disinfect the tank.
4.Wipe the heating element clean with a soft cloth after it has had a chance to cool.
Disinfect tank:
1.Fill tank with 1 teaspoon of bleach and 3.5 litres of water.
2.Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces.
3.Empty the tank after 20 minutes, and rinse well with water until the bleach smell is gone. Dry with some paper towel.
4.Refill the water tank with cool water; replace the water tank. Repeat Operating Instructions.
Storage Instructions
If your humidifier will not be in use for two days or more, or at the end of the season follow these instructions.
1.Clean, rinse and thoroughly dry the humidifier as directed in the De-scaling Maintenance section. DO NOT leave any water inside the base or tray.
2.Remove the reservoir cap. Do not store with the reservoir cap in place.
3.Remove and throw away the filter
4.Place the humidifier in the original carton and store in a cool, dry place.
5.Clean the humidifier before the next season begins.
6.Order a replacement filter to start the next season.
SERVICE INSTRUCTIONS
1.Do NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. The insides of the unit contain no user serviceable parts. Only qualified personnel should perform all servicing.
2.Should the unit stop working, first check the fuse in the plug (UK only) or fuse/circuit breaker at the distribution board is operating, before contacting the manufacturer or service agent.
3.If you need to exchange the unit, please return it in its original carton, with a sales receipt, to the store where you purchased it.
4.Should your humidifier require service, please contact your local dealer.
ACCESSORIES FOR MODEL BWM5075
•WMF-50 Water Purification Filter
•We recommend the use of a Bionaire™ / Hygrometer/ Thermometer, model NO: BT400, to read the indoor room temperature and humidity level.
•Bionaire™ Cleaning Solution
TECHNICAL SPECIFICATIONS
Input voltage: | 220-240 V~ 50 Hz |
Power consumption: | 400 Watts (max) |
The Holmes Group reserves the right to change or modify any specifications without notice.
THIS PRODUCT IS MANUFACTURED TO COMPLY WITH THE E.E.C. DIRECTIVES
73/23/EEC and 89/336/EEC.
For U.K. and Ireland only:
If the plug is not suitable for the socket outlets in your home, it can be removed and replaced by a plug of the correct type.
Please refer to "Installation of a plug" below.
Installation of a plug Applicable to U.K. and Ireland.
WARNING - THIS APPLIANCE MUST BE EARTHED
The wires in the mains lead are coloured as such:
GREEN AND YELLOW | - EARTH |
BROWN | - LIVE |
BLUE | - NEUTRAL |
Please note that the colour of these mains wires may not correspond with the colour markings that identify the terminals in your plug.
Please proceed as follows:
The wire which is coloured GREEN AND YELLOW must be connected to the terminal which is marked with the letter 'E' or by the earth symbol or coloured GREEN or GREEN AND YELLOW.
The BROWN coloured wire must be connected to the terminal, which is marked with the letter "L" or is coloured RED.
The BLUE coloured wire must be connected to the terminal, which is marked with the letter "N" or is coloured BLACK.
5