3-5-1(c) Cable Connection
(S.G) | 1 | 1 | (S.G) |
(TXD) | 2 | 2 | (TXD) |
(RXD) | 3 | 3 | (RXD) |
Printer |
|
| Host |
Side(25P) |
|
| Side(25P) |
(DSR) | 6 | 6 | (DSR) |
(DTR) 20 | 20 (DTR) | ||
(S.G) | 7 | 7 | (S.G) |
|
|
|
|
Figure
3-5-1(d) Signal Description
Pin No. | Signal Name | Signal Direction |
| Function | |
BODY | Frame GND | - | Frame Ground | ||
2 | TXD | Output | Transmit Data | ||
3 | RXD | Input | Receive Data | ||
|
|
| This signal indicates whether the host computer can receive | ||
|
|
| data. (H/W flow control) | ||
|
|
| 1) | MARK(Logic1) : The host can receive a data. | |
6 | DSR | Input | 2) | SPACE(Logic0) : The host can not receive a data. | |
3) The printer transmits a data to the host, after confirming | |||||
|
|
|
| this signal. | |
|
|
| 4) | When XON/XOFF flow control is selected, the printer | |
|
|
| does | ||
|
|
|
| not check this signal. | |
7 | Signal GND | - | Signal Ground | ||
|
|
| This signal indicates whether the printer is busy. (H/W flow | ||
|
|
| control) | ||
|
|
| 1) | MARK(Logic1) : The printer is busy. | |
20 | DTR | Output | 2) | SPACE(Logic0) : The printer is not busy. | |
3) The host transmits a data to the printer, after confirming | |||||
|
|
| |||
|
|
|
| this signal. | |
|
|
| 4) | When XON/XOFF flow control is selected, the host does | |
|
|
|
| not check this signal. | |
|
| Table |
Rev. 2.01 | - 25 - |