7-2 System Problem

 

 

SRP-350/352plusA&C

7-2 System Problem

 

 

System

 

 

Problem

 

 

Reset Signal

N

 

Ok?

 

 

Y

1.

Check the IC (U8,ASM811REUSF-T)

 

2.

Check the Reset Pin on Flash Memory and CPU

 

3.

Check the related Circuit & Pattern on PCB

Clock

N

 

Signal Ok?

 

 

Y

1.

Check the Frequency (5MHz)

 

2.

Check the related Circuit & Pattern on PCB

Program

N

 

Ok?

 

 

Y

1.

Check the Address/Data Line Pattern

 

2.

Check the related Circuit & Pattern on PCB

 

3.

Program download again

SRAM

N

 

Ok?

 

 

Y

1.

Check the /CS Signal

 

2.

Check the SRAM

 

3.

Check the Address/Data Pattern

CPU

N

 

Ok?

 

 

Y

1.

Check the Main Clock (5MHz)

 

2.

Check the Address/Data Pattern

 

3.

Check the Main PBA