7-9 USB2.0 Communication Problem

SRP-350/352plusA&C

7-9 USB2.0 Communication Problem

USB

Problem

Main PBA I/F

Y

Failure?

 

 

N

 

1.Check the Control Line & Signal (/CS_U,/RD,/LWR,USB_/IRQ)

2.Check the Data Line and Signal

3.Check the Connector (34P)

4.Check the Clock (30MHz)

5.Check the related Circuit & Pattern on Main PBA

Reverse Mode

Y

Failure?

 

 

N

 

1.Check the Clock (30MHz)

2.Check the Host whether it works correctly

3.Check the USB Cable whether it is open or shot

4.Check the related Circuit & Pattern on Main PBA

End

Rev. 2.01

- 59 -

Page 59
Image 59
BIXOLON service manual 7-9 USB2.0 Communication Problem, SRP-350/352plusA&C, Main PBA I/F, Failure?, Reverse Mode