7-5 Auto Cutter and Drawer Problem

SRP-350/352plusA&C

7-5 Auto Cutter and Drawer Problem

Auto Cutter

Problem

Auto Cutter

OK?

N

Y

Auto Cutter

S/W Ok?

N

1.Check the Signal on CPU

2.Check the Output Signal of U13 (TA8428K)

3.Check the Harness

4.Check the Auto Cutter Assembly (Motor, Cutter...)

Y

End

Drawer

Problem

Drawer Open

Failure?

Y

1.Check the Signal on CPU

2.Check the Harness

3.Check the Micro S/W in the Auto Cutter Assembly

N

Compulsory

Failure?

Y

1.Check the Drawer Connector & Harness

2.Check the Drawer Signals on CPU (P33, P34)

3.Check the related circuit & Component 2SD2170 (Q10, Q11)

4.Check the Solenoid in the Drawer

N

1.Check the Compulsory Harness & Connector

2.Check the Micro switch in the Drawer

End