IMPORTANT: Observe all governing codes and ordinances. Check the location where the air conditioner will be installed. Make sure you have everything necessary for correct installation. The location should provide:

Grounded electrical outlet within 4 ft (122 cm) of where the power cord exits the air conditioner.

NOTE: Do not use an extension cord. Free movement of air in room to be cooled.

A large enough opening for the air conditioner. Installation parts are supplied for double-hung windows.

Adequate walt support for weight of air conditioner. Air conditioner weighs 134.7 lbs to 163.13 lbs (61.1 kg to 74 kg).

NOTE: Cabinet louvers must not be obstructed. Air must be able to pass freely through the cabinet louvers.

A. Cabinet louvers

Window Installation

Window opening measurements:

30" minimum to 41" (76.2 cm to 101.1 cm) maximum opening width.

23% " (130.6 cm) minimum opening height.

__A__t_

B

I

F

[J

A. 30_" (76.2 cm) minimum

B. 23s/8" (130.6 cm)*ninimum

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

The electrical ratings for your air conditioner are listed on the model and serial number label, The model and serial number label is located either on the side or back of the air conditioner

cabinet or behind the front grille,

Specific electrical requirements are listed in the chart below. Follow the requirements for the type of plug on the power supply cord.

Power
Supply

 

 

Cord

 

Wiring Requirements

?

ii

115-volt

(103,5 min. to 126.5 max,)

 

0 to 12 amps

 

ii

15-amp

time-delay fuse or circuit

 

 

breaker

 

 

 

Use on single outlet circuit only.

 

Model: BWE15A

 

 

 

 

 

Power

Supply

 

 

Cord

 

Wiring

Requirements

 

208/230-volt (187 min. to 253

max.)

_'/'_,,1_

 

0 to 12 amps

 

 

::20-amp time-delay fuse or circuit breaker

Use on single outlet circuit only.

Model: BWE18A

BWE25A

 

 

Recommended

Grounding Method

 

This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a 3 prong grounding plug. The cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer's responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer.

It is the customer's responsibility:

To contact a qualified electrical installer.